Prospective Paired Comparison of MRI- and CT-Based Planning for Adjuvant Vaginal Cuff Brachytherapy in Endometrial Cancer: An Exploratory Study

Objectives: To assess the impact of magnetic resonance imaging (MRI) versus computed tomography (CT) on target delineation and dosimetry in adjuvant vaginal cuff brachytherapy (VBT) for endometrial cancer. Methods: Twenty-five consecutive patients receiving adjuvant high-dose-rate VBT after hysterectomy were prospectively included. All underwent standardized treatment of 4 × 5 Gy in 5 mm tissue depth using a vaginal cylinder with a fixed loading pattern; individualized optimization was permitted for suboptimal coverage or proximity of organs at risk (OARs). For each patient, clinical target volume (CTV) and OARs (bladder, rectum, sigmoid, bowel) were contoured on both CT and MRI of the first fraction. Dosimetric parameters (CTV D90, D98, D50; OAR D2cc) were compared. Treatment characteristics and outcomes were analyzed retrospectively. Results: Median CTV was smaller on MRI (9.8 cm3) than on CT (13.6 cm3). CTV coverage was comparable between modalities, with mean EQD2 D90 of 5.32 Gy per fraction on MRI versus 5.10 Gy per fraction on CT (p = 0.433) and mean EQD2 D98 of 3.95 Gy per fraction on MRI versus 3.80 Gy per fraction on CT (p = 0.491). In contrast, EQD2 D50 was significantly higher on MRI-based plans than on CT-based plans (9.12 vs. 8.62 Gy per fraction, p = 0.012). OAR D2cc values showed no significant differences between modalities. Most patients (80%) were treated with the institutional standard plan, and 20% required individualized optimization. After a median follow-up of 25 months (range 0–72), five patients (20%) recurred (one local, one regional, three distant), and one (4%) died. No grade ≥ 3 gastrointestinal or genitourinary toxicities occurred among patients with available data. Conclusions: In this small exploratory cohort, MRI-based planning delineated smaller CTVs, whereas the evaluated target-coverage and OAR-dose parameters were broadly similar between modalities. These findings suggest that CT-based planning may be adequate for many routine cases, with MRI potentially useful for selected, anatomically complex patients. Confirmation in larger multicenter studies is required.

Authors

Institutions

Publication Details

Journal
Radiation
Published
2026-10-13
DOI
https://doi.org/10.3390/radiation6040038
Primary Topic
Endometrial and Cervical Cancer Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prospective Paired Comparison of MRI- and CT-Based Planning for Adjuvant Vaginal Cuff Brachytherapy in Endometrial Cancer: An Exploratory Study

Johannes Knoth, Claudia Gösenbauer, Aleksandra Winkler, Alina Sturdza et al.
Radiation
Endometrial and Cervical Cancer Treatments
article

Prospective Paired Comparison of MRI- and CT-Based Planning for Adjuvant Vaginal Cuff Brachytherapy in Endometrial Cancer: An Exploratory Study

Johannes Knoth, Claudia Gösenbauer, Aleksandra Winkler, Alina Sturdza, Vincent Dick, Iustin-Mihai Pirsan
article en

Abstract

Objectives: To assess the impact of magnetic resonance imaging (MRI) versus computed tomography (CT) on target delineation and dosimetry in adjuvant vaginal cuff brachytherapy (VBT) for endometrial cancer. Methods: Twenty-five consecutive patients receiving adjuvant high-dose-rate VBT after hysterectomy were prospectively included. All underwent standardized treatment of 4 × 5 Gy in 5 mm tissue depth using a vaginal cylinder with a fixed loading pattern; individualized optimization was permitted for suboptimal coverage or proximity of organs at risk (OARs). For each patient, clinical target volume (CTV) and OARs (bladder, rectum, sigmoid, bowel) were contoured on both CT and MRI of the first fraction. Dosimetric parameters (CTV D90, D98, D50; OAR D2cc) were compared. Treatment characteristics and outcomes were analyzed retrospectively. Results: Median CTV was smaller on MRI (9.8 cm3) than on CT (13.6 cm3). CTV coverage was comparable between modalities, with mean EQD2 D90 of 5.32 Gy per fraction on MRI versus 5.10 Gy per fraction on CT (p = 0.433) and mean EQD2 D98 of 3.95 Gy per fraction on MRI versus 3.80 Gy per fraction on CT (p = 0.491). In contrast, EQD2 D50 was significantly higher on MRI-based plans than on CT-based plans (9.12 vs. 8.62 Gy per fraction, p = 0.012). OAR D2cc values showed no significant differences between modalities. Most patients (80%) were treated with the institutional standard plan, and 20% required individualized optimization. After a median follow-up of 25 months (range 0–72), five patients (20%) recurred (one local, one regional, three distant), and one (4%) died. No grade ≥ 3 gastrointestinal or genitourinary toxicities occurred among patients with available data. Conclusions: In this small exploratory cohort, MRI-based planning delineated smaller CTVs, whereas the evaluated target-coverage and OAR-dose parameters were broadly similar between modalities. These findings suggest that CT-based planning may be adequate for many routine cases, with MRI potentially useful for selected, anatomically complex patients. Confirmation in larger multicenter studies is required.

RadiationVol. 6(4)
Vienna General Hospital (AT), Comprehensive Cancer Center Vienna (AT)
Openalex Percentile: Top 8%
Endometrial and Cervical Cancer Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.