A comprehensive validation of an electrical–thermal model for bifacial photovoltaic modules

This study focuses on the representation of bifacial photovoltaic modules using electrical and thermal models. Various approaches in the literature propose modifications, such as incorporating rear-side irradiance, adjusting resistive parameters and diode currents, and adding series resistances. However, experimental evidence for evaluating these approaches under different operating conditions remains limited. Moreover, most studies concentrate on the maximum power point without analyzing the full IV curve, which can reveal shading-induced steps associated with rear-side frame shading in commercial photovoltaic modules. An integrated electrical and thermal model for bifacial modules is proposed, employing a single-diode model for the electrical component. To represent bifacial behavior, parameters for both front and rear sides are integrated using irradiance-based rescaling, including temperature corrections to derive IV curves and estimate power output. For the thermal component, two approaches are employed, culminating in a hybrid model that selects between the Gu and Faiman formulations according to irradiance conditions. Irradiance estimation is performed using Bifacial Radiance software. Validation of the proposed model involves two tests. The first employs laboratory measurements using an A+A+A+ solar simulator to generate IV curves under controlled conditions. The second uses an outdoor setup with a vertically oriented, east–west bifacial module that continuously monitors irradiance, temperature, voltage, and current. The proposed electrical model reproduced the indoor IV curves with deviations of approximately 3% at the maximum power point. Under outdoor conditions, additional discrepancies were observed and were associated with irradiance variability, temporal resolution, and shading from the module frame and surrounding structure.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2026-10-13
DOI
https://doi.org/10.1016/j.enconman.2026.122222
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comprehensive validation of an electrical–thermal model for bifacial photovoltaic modules

Patricio Valdivia, Antonio Sánchez‐Squella, Jesús García, Rodrigo Barraza et al.
Energy Conversion and Management
Photovoltaic System Optimization Techniques
article

A comprehensive validation of an electrical–thermal model for bifacial photovoltaic modules

Patricio Valdivia, Antonio Sánchez‐Squella, Jesús García, Rodrigo Barraza, Valentina González Becerra
article en

Abstract

This study focuses on the representation of bifacial photovoltaic modules using electrical and thermal models. Various approaches in the literature propose modifications, such as incorporating rear-side irradiance, adjusting resistive parameters and diode currents, and adding series resistances. However, experimental evidence for evaluating these approaches under different operating conditions remains limited. Moreover, most studies concentrate on the maximum power point without analyzing the full IV curve, which can reveal shading-induced steps associated with rear-side frame shading in commercial photovoltaic modules. An integrated electrical and thermal model for bifacial modules is proposed, employing a single-diode model for the electrical component. To represent bifacial behavior, parameters for both front and rear sides are integrated using irradiance-based rescaling, including temperature corrections to derive IV curves and estimate power output. For the thermal component, two approaches are employed, culminating in a hybrid model that selects between the Gu and Faiman formulations according to irradiance conditions. Irradiance estimation is performed using Bifacial Radiance software. Validation of the proposed model involves two tests. The first employs laboratory measurements using an A+A+A+ solar simulator to generate IV curves under controlled conditions. The second uses an outdoor setup with a vertically oriented, east–west bifacial module that continuously monitors irradiance, temperature, voltage, and current. The proposed electrical model reproduced the indoor IV curves with deviations of approximately 3% at the maximum power point. Under outdoor conditions, additional discrepancies were observed and were associated with irradiance variability, temporal resolution, and shading from the module frame and surrounding structure.

Energy Conversion and ManagementVol. 372
Universidad de Santiago de Chile (CL), Austral University of Chile (CL), Adolfo Ibáñez University (CL), Federico Santa María Technical University (CL)
Agencia Nacional de Investigación y Desarrollo
Openalex Percentile: Top 34%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.