Progression of Tricuspid Regurgitation After Cardiac Implantable Electronic Device Implantation and Its Impact on Mortality and Hospitalization: A Single‐Center Cohort Study

INTRODUCTION: Tricuspid regurgitation (TR) progression is a recognized complication of cardiac implantable electronic device (CIED) implantation, yet its prognostic impact on long-term clinical outcomes remains incompletely defined. METHODS AND RESULTS: In this single-center retrospective cohort, 303 patients undergoing CIED implantation between 2005 and 2023 were followed for a median of 4.8 years. TR severity was assessed echocardiographically at baseline and 12 months. The primary endpoint was TR progression (≥ 1-grade worsening); secondary endpoints were all-cause mortality, cardiovascular hospitalization, their composite, and progression to severe TR, analyzed by Kaplan-Meier and Cox regression. TR progressed in 103 patients (34.0%), regressed in 33 (10.9%), and remained stable in 167 (55.1%), a net rightward shift (p < 0.001). Progression differed by device type (p = 0.031): among the larger subgroups, VVI-ICD showed the greatest net progression (31.8% worsened vs. 6.9% improved; p < 0.001) and CRT-D the highest regression (18.8%). During follow-up, 67 patients (22.1%) died and 164 (54.1%) were hospitalized. Overall TR progression was not independently associated with mortality (HR 1.118, p = 0.693) but independently predicted cardiovascular hospitalization (HR 1.640, p = 0.003) and the composite endpoint (HR 1.480, p = 0.014). On unadjusted analysis, progression specifically to severe TR (n = 15) was associated with increased mortality (HR 1.99, p = 0.024) and cardiovascular hospitalization (HR 2.45, p < 0.001). CONCLUSION: TR progression occurs in approximately one-third of CIED recipients within the first year and independently predicts cardiovascular hospitalization. Progression to severe TR identifies a higher-risk subset, supporting routine post-implant echocardiographic surveillance.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Electrophysiology
Published
2026-10-13
DOI
https://doi.org/10.1111/jce.70532
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Progression of Tricuspid Regurgitation After Cardiac Implantable Electronic Device Implantation and Its Impact on Mortality and Hospitalization: A Single‐Center Cohort Study

Evrim Şimşek, Filiz Özerkan Çakan, Ahmet Can Urgancı
Journal of Cardiovascular Electrophysiology
Cardiac Valve Diseases and Treatments
article

Progression of Tricuspid Regurgitation After Cardiac Implantable Electronic Device Implantation and Its Impact on Mortality and Hospitalization: A Single‐Center Cohort Study

Evrim Şimşek, Filiz Özerkan Çakan, Ahmet Can Urgancı
article en

Abstract

INTRODUCTION: Tricuspid regurgitation (TR) progression is a recognized complication of cardiac implantable electronic device (CIED) implantation, yet its prognostic impact on long-term clinical outcomes remains incompletely defined. METHODS AND RESULTS: In this single-center retrospective cohort, 303 patients undergoing CIED implantation between 2005 and 2023 were followed for a median of 4.8 years. TR severity was assessed echocardiographically at baseline and 12 months. The primary endpoint was TR progression (≥ 1-grade worsening); secondary endpoints were all-cause mortality, cardiovascular hospitalization, their composite, and progression to severe TR, analyzed by Kaplan-Meier and Cox regression. TR progressed in 103 patients (34.0%), regressed in 33 (10.9%), and remained stable in 167 (55.1%), a net rightward shift (p < 0.001). Progression differed by device type (p = 0.031): among the larger subgroups, VVI-ICD showed the greatest net progression (31.8% worsened vs. 6.9% improved; p < 0.001) and CRT-D the highest regression (18.8%). During follow-up, 67 patients (22.1%) died and 164 (54.1%) were hospitalized. Overall TR progression was not independently associated with mortality (HR 1.118, p = 0.693) but independently predicted cardiovascular hospitalization (HR 1.640, p = 0.003) and the composite endpoint (HR 1.480, p = 0.014). On unadjusted analysis, progression specifically to severe TR (n = 15) was associated with increased mortality (HR 1.99, p = 0.024) and cardiovascular hospitalization (HR 2.45, p < 0.001). CONCLUSION: TR progression occurs in approximately one-third of CIED recipients within the first year and independently predicts cardiovascular hospitalization. Progression to severe TR identifies a higher-risk subset, supporting routine post-implant echocardiographic surveillance.

Journal of Cardiovascular Electrophysiology
Ege University (TR)
Openalex Percentile: Top 12%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.