Development of a Magnetic Bead-Based Electrochemical Immunoassay for Human Immunodeficiency Virus Type 1 p24 Antigen Detection

Early and sensitive detection of human immunodeficiency virus 1 (HIV-1) p24 antigen is crucial for identifying acute infection before seroconversion and monitoring low-level viremia. Here, we report a magnetic bead (MB)-based electrochemical immunoassay using stencil-printed carbon electrodes, systematically comparing streptavidin-, tosyl-, and N-hydroxysuccinimide-MBs for p24 detection. Tosyl-MBs achieved superior analytical performance with limits of detection of 19.4 pg/mL in tris-buffered saline with Tween 20, 24.3 pg/mL in media containing viral lysis buffer, and 8.8 pg/mL in human serum, demonstrating excellent matrix tolerance and reproducibility across the clinically relevant concentration range. The sandwich immunoassay employed optimized capture and horseradish peroxidase-conjugated detection antibodies with chronoamperometric readout using 3,3',5,5'-tetramethylbenzidine substrate at 0.0 V vs a silver pseudoreference electrode, enabling rapid immunocomplex quantification on magnet-retained beads with minimal sample handling. Tosyl-MBs provided the strongest concentration-dependent response across all matrices tested, with surface chemistry influencing antibody immobilization efficiency, nonspecific background signal, and p24 capture capacity. The platform demonstrated stability for at least 28 days under storage conditions and successfully distinguished inactivated HIV-1 samples from negative controls, thereby establishing tosyl-MB electrochemical immunoassays that are compatible with serum and other complex biological matrices. Further validation with clinical specimens, integration of simplified sample-processing steps, and implementation in portable instrumentation will be required to assess their potential for future point-of-care HIV diagnostics.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-10-13
DOI
https://doi.org/10.1021/acssensors.6c02479
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Magnetic Bead-Based Electrochemical Immunoassay for Human Immunodeficiency Virus Type 1 p24 Antigen Detection

Charles S. Henry, Alex J. Rai, M. M. Bridges, Thaísa A. Baldo et al.
ACS Sensors
Electrochemical sensors and biosensors
article

Development of a Magnetic Bead-Based Electrochemical Immunoassay for Human Immunodeficiency Virus Type 1 p24 Antigen Detection

Charles S. Henry, Alex J. Rai, M. M. Bridges, Thaísa A. Baldo, David S. Dandy, Brian J. Geiss, Brooke M. Enney, Bethany Unruh, Matthew Lynd, Nicole Villarini
article en

Abstract

Early and sensitive detection of human immunodeficiency virus 1 (HIV-1) p24 antigen is crucial for identifying acute infection before seroconversion and monitoring low-level viremia. Here, we report a magnetic bead (MB)-based electrochemical immunoassay using stencil-printed carbon electrodes, systematically comparing streptavidin-, tosyl-, and N-hydroxysuccinimide-MBs for p24 detection. Tosyl-MBs achieved superior analytical performance with limits of detection of 19.4 pg/mL in tris-buffered saline with Tween 20, 24.3 pg/mL in media containing viral lysis buffer, and 8.8 pg/mL in human serum, demonstrating excellent matrix tolerance and reproducibility across the clinically relevant concentration range. The sandwich immunoassay employed optimized capture and horseradish peroxidase-conjugated detection antibodies with chronoamperometric readout using 3,3',5,5'-tetramethylbenzidine substrate at 0.0 V vs a silver pseudoreference electrode, enabling rapid immunocomplex quantification on magnet-retained beads with minimal sample handling. Tosyl-MBs provided the strongest concentration-dependent response across all matrices tested, with surface chemistry influencing antibody immobilization efficiency, nonspecific background signal, and p24 capture capacity. The platform demonstrated stability for at least 28 days under storage conditions and successfully distinguished inactivated HIV-1 samples from negative controls, thereby establishing tosyl-MB electrochemical immunoassays that are compatible with serum and other complex biological matrices. Further validation with clinical specimens, integration of simplified sample-processing steps, and implementation in portable instrumentation will be required to assess their potential for future point-of-care HIV diagnostics.

ACS Sensors
Columbia University Irving Medical Center (US), Colorado State University (US)
National Institutes of Health
Openalex Percentile: Top 23%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.