UV-derived scattering as a high-throughput readout for adeno-associated virus-like particle separation screenings

Virus-like particles (VLPs), including those derived from adeno-associated virus (AAV), are increasingly investigated for vaccination, capsid engineering, and gene-delivery applications. Although precipitation and aqueous two-phase separation (ATPS) represent promising alternatives to adsorption-based capture, their optimization is limited by the lack of rapid analytical methods suitable for complex process samples. Here, VP3-only AAV5 VLPs produced in Escherichia coli were used as a model system to evaluate UV-derived light scattering as a high-throughput separation readout. Blank-corrected absorbance at 320 nm was used as a relative descriptor of particulate-associated scattering, while scattering-corrected absorbance at 280 nm monitored the soluble biomolecular fraction. During PEG precipitation, A320 showed condition-dependent agreement with anti-AAV5 ELISA, with the closest correspondence for PEG4000 and increasing divergence at lower PEG molecular weights. Capsid-spiking experiments further showed that dispersed intact capsids alone contributed only marginally to A320, indicating that the signal primarily reflects larger scattering-active structures accompanying capsid depletion. The workflow enabled screening and analysis of 170 precipitation and PEG/phosphate ATPS conditions in biological duplicate within 3 days. Low-molecular-weight PEG systems provided stronger separation between soluble biomolecular material and particulate-associated scattering. In PEG400 ATPS, pH altered the distribution of scattering-active material and capsids between the liquid phases and interphase, whereas selected precipitation conditions showed higher recovery of assembled capsids after resolubilization than ATPS, at the expense of lower impurity removal. Overall, UV-derived scattering provides a rapid, scalable first-line readout for comparing separation conditions and reducing the number of samples requiring capsid-specific and structural characterization.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-10-13
DOI
https://doi.org/10.3389/fbioe.2026.1913731
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

UV-derived scattering as a high-throughput readout for adeno-associated virus-like particle separation screenings

Malte Schwarzer, Jürgen Hubbuch, Giulia Polazzo
Frontiers in Bioengineering and Biotechnology
Protein purification and stability
article

UV-derived scattering as a high-throughput readout for adeno-associated virus-like particle separation screenings

Malte Schwarzer, Jürgen Hubbuch, Giulia Polazzo
article en

Abstract

Virus-like particles (VLPs), including those derived from adeno-associated virus (AAV), are increasingly investigated for vaccination, capsid engineering, and gene-delivery applications. Although precipitation and aqueous two-phase separation (ATPS) represent promising alternatives to adsorption-based capture, their optimization is limited by the lack of rapid analytical methods suitable for complex process samples. Here, VP3-only AAV5 VLPs produced in Escherichia coli were used as a model system to evaluate UV-derived light scattering as a high-throughput separation readout. Blank-corrected absorbance at 320 nm was used as a relative descriptor of particulate-associated scattering, while scattering-corrected absorbance at 280 nm monitored the soluble biomolecular fraction. During PEG precipitation, A320 showed condition-dependent agreement with anti-AAV5 ELISA, with the closest correspondence for PEG4000 and increasing divergence at lower PEG molecular weights. Capsid-spiking experiments further showed that dispersed intact capsids alone contributed only marginally to A320, indicating that the signal primarily reflects larger scattering-active structures accompanying capsid depletion. The workflow enabled screening and analysis of 170 precipitation and PEG/phosphate ATPS conditions in biological duplicate within 3 days. Low-molecular-weight PEG systems provided stronger separation between soluble biomolecular material and particulate-associated scattering. In PEG400 ATPS, pH altered the distribution of scattering-active material and capsids between the liquid phases and interphase, whereas selected precipitation conditions showed higher recovery of assembled capsids after resolubilization than ATPS, at the expense of lower impurity removal. Overall, UV-derived scattering provides a rapid, scalable first-line readout for comparing separation conditions and reducing the number of samples requiring capsid-specific and structural characterization.

Frontiers in Bioengineering and BiotechnologyVol. 14
Karlsruhe Institute of Technology (DE)
HORIZON EUROPE Marie Sklodowska-Curie Actions
Openalex Percentile: Top 24%
Protein purification and stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.