Evaluating Perfusion Quantification for Phase‐Resolved Functional Lung MRI Using Gaussian Filtering
ABSTRACT Phase‐resolved functional lung (PREFUL) MRI enables contrast‐free lung perfusion quantification (Q Quant ). Current quantification uses a single median value per slice of maximal blood exchange fraction (ΔS), which limits regional assessment, whereas regional ΔS causes artifacts. This retrospective study aims to optimize Q Quant by applying Gaussian filtering to ΔS to improve intrascan/interscan repeatability in healthy volunteers, while evaluating whether the optimized Q Quant retains agreement with dynamic contrast‐enhanced (DCE) MRI in chronic obstructive pulmonary disease (COPD) and chronic thromboembolic pulmonary hypertension (CTEPH) patients and exhibits a physiologically plausible gravity‐dependent perfusion gradient. Analysis was performed on 29 healthy subjects (11 female, age: 19–33 years), 20 COPD patients (three female, age: 46–76 years) and 15 CTEPH patients (six female, age: 44–82 years), scanned at 1.5 T. Healthy subjects underwent four PREFUL scans in two sessions. Patients just underwent one PREFUL and DCE scan. Q Quant maps were calculated while applying different Gaussian filter options to ΔS. In patients, PREFUL‐derived Q Quant maps were coregistered to DCE‐derived pulmonary blood flow (PBF) maps for global and voxel‐wise correlations. In healthy subjects, the gravity‐dependent perfusion gradient was quantified by linear regression of slice‐wise Q Quant across five coronal slices. Gaussian filtering ΔS with σ = 1.5 improved intrascan and interscan repeatability in healthy subjects (mean bias: ≤ 2.94 mL/100 mL; Cohen's d : 0.2) compared with the current slice median setting (mean bias: ≥ 3.75 mL/100 mL; Cohen's d : 0.68). Correlations with PBF remained stable after filtering (σ = 1.5) in COPD (filtered vs. default ΔS: global r = 0.57 vs. r = 0.59, voxel‐wise r = 0.32 vs. r = 0.32) and CTEPH (global r = 0.32 vs. r = 0.28, voxel‐wise r = 0.40 vs. r = 0.41), all significant except global CTEPH. The filtered Q Quant maps showed a significant gravity‐dependent perfusion gradient (ΔS filtered σ = 1.5) of 1.47 mL/min/100 mL/cm. Gaussian filtering ΔS with σ = 1.5 improved Q Quant repeatability while preserving DCE‐MRI agreement and is therefore recommended. The observed gravity‐dependent perfusion gradient confirms physiological plausibility, supporting potential in clinical use.
Authors
- Kirsten Johanna Schmidt
- Marius Wernz (ORCID: https://orcid.org/0009-0003-0452-8574)
- Filip Klimeš (ORCID: https://orcid.org/0000-0003-2715-0757)
- Julian Glandorf (ORCID: https://orcid.org/0000-0003-1927-9876)
- Andreas Voskrebenzev (ORCID: https://orcid.org/0000-0001-5699-1841)
- Lea Behrendt (ORCID: https://orcid.org/0000-0001-8851-1849)
- Jens Vogel‐Claussen (ORCID: https://orcid.org/0000-0001-5595-6948)
- Frank K. Wacker (ORCID: https://orcid.org/0000-0002-6285-8403)
Institutions
- Medizinische Hochschule Hannover (DE)
- Humboldt-Universität zu Berlin (DE)
- German Center for Lung Research (DE)
- Freie Universität Berlin (DE)
- Charité - Universitätsmedizin Berlin (DE)
Publication Details
- Journal
- NMR in Biomedicine
- Published
- 2026-10-13
- DOI
- https://doi.org/10.1002/nbm.70420
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Deutsches Zentrum für Lungenforschung