Laser-induced fluorescence temperature mapping in microfluidics: Calibration strategy and application to AC electrothermal microflows

This paper presents a non-invasive laser-induced fluorescence (LIF) approach for temperature mapping in microfluidic chambers and then applies it to an alternating-current electrothermal (ACET) flow considered as a representative electro-microfluidic test case. Temperature mapping remains difficult when the device height is only a few hundred micrometers and when intrusive probes would disturb either the hydrodynamic field or the applied electric field. Rhodamine B dissolved in physiological saline is therefore characterized independently in absorbance and fluorescence before being used as a temperature-sensitive tracer. At a concentration as small as 1 × 10 -4 mol/L, the Beer–Lambert regime is retained over the optical path of the microchannel, absorbance is weakly affected by temperature in the range of interest, and the fluorescence intensity decreases linearly with a sensitivity of approximately 1.78 %/K between 20 °C and 45 °C. The calibrated LIF measurements are complemented by micro-particle image velocimetry measurements performed in separate experimental runs in a saline-filled microchannel equipped with a pair of coplanar electrodes. In this demonstrator, the temperature gradient, not imposed externally, is generated by Joule heating associated with conduction currents, and it is coupled with the non-uniform AC electric field to produce ACET forcing. A three-dimensional electro-thermo-hydrodynamic model, based on quasi-static electrostatics, Navier–Stokes equations, and energy equation with Joule heating and temperature-dependent electrical properties included, is used to interpret and validate the measurements. Both simulations and experiments reveal a quadripolar four-clover velocity pattern above the electrode gap. Experimentally, the peak velocity reaches 350 µm/s for a 20 V peak-to-peak actuation at an AC frequency of 1 MHz, while fluorescence thermometry reveals moderate temperature rise, below about 10 K up to 25 V peak-to-peak. The present methodology thus establishes a calibrated thermal diagnostic and demonstrates its ability to assess heat transfer and flow organization in electrofluidic microsystems, thus confirming its ability to prevent denaturation of biological targets, for instance.

Authors

Institutions

Publication Details

Journal
International Journal of Heat and Mass Transfer
Published
2026-10-13
DOI
https://doi.org/10.1016/j.ijheatmasstransfer.2026.129711
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laser-induced fluorescence temperature mapping in microfluidics: Calibration strategy and application to AC electrothermal microflows

Laurent Davoust, Jean-Maxime Roux, Lena Gonzalez
International Journal of Heat and Mass Transfer
Microfluidic and Capillary Electrophoresis Applications
article

Laser-induced fluorescence temperature mapping in microfluidics: Calibration strategy and application to AC electrothermal microflows

Laurent Davoust, Jean-Maxime Roux, Lena Gonzalez
article en

Abstract

This paper presents a non-invasive laser-induced fluorescence (LIF) approach for temperature mapping in microfluidic chambers and then applies it to an alternating-current electrothermal (ACET) flow considered as a representative electro-microfluidic test case. Temperature mapping remains difficult when the device height is only a few hundred micrometers and when intrusive probes would disturb either the hydrodynamic field or the applied electric field. Rhodamine B dissolved in physiological saline is therefore characterized independently in absorbance and fluorescence before being used as a temperature-sensitive tracer. At a concentration as small as 1 × 10 -4 mol/L, the Beer–Lambert regime is retained over the optical path of the microchannel, absorbance is weakly affected by temperature in the range of interest, and the fluorescence intensity decreases linearly with a sensitivity of approximately 1.78 %/K between 20 °C and 45 °C. The calibrated LIF measurements are complemented by micro-particle image velocimetry measurements performed in separate experimental runs in a saline-filled microchannel equipped with a pair of coplanar electrodes. In this demonstrator, the temperature gradient, not imposed externally, is generated by Joule heating associated with conduction currents, and it is coupled with the non-uniform AC electric field to produce ACET forcing. A three-dimensional electro-thermo-hydrodynamic model, based on quasi-static electrostatics, Navier–Stokes equations, and energy equation with Joule heating and temperature-dependent electrical properties included, is used to interpret and validate the measurements. Both simulations and experiments reveal a quadripolar four-clover velocity pattern above the electrode gap. Experimentally, the peak velocity reaches 350 µm/s for a 20 V peak-to-peak actuation at an AC frequency of 1 MHz, while fluorescence thermometry reveals moderate temperature rise, below about 10 K up to 25 V peak-to-peak. The present methodology thus establishes a calibrated thermal diagnostic and demonstrates its ability to assess heat transfer and flow organization in electrofluidic microsystems, thus confirming its ability to prevent denaturation of biological targets, for instance.

International Journal of Heat and Mass TransferVol. 273
Institut polytechnique de Grenoble (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Science et Ingénierie des Matériaux et Procédés (FR), Laboratoire d'Électronique des Technologies de l'Information (FR), Université Grenoble Alpes (FR)
Commissariat à l'Énergie Atomique et aux Énergies Alternatives
Openalex Percentile: Top 24%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.