Intraoperative Posterior Migration of the Odontoid Fragment During Posterior C1–C2 Screw–Rod Fixation for Acute Type II Dens Fractures: A Technical Case Series

Abstract Posterior C1–C2 screw–rod fixation is a well-established treatment for unstable type II odontoid fractures. Although these constructs allow controlled reduction in atlantoaxial pathology, their effect on the mobile odontoid fragment during acute type II dens fracture fixation remains insufficiently described. We describe a series of patients in whom intraoperative posterior migration of the odontoid fragment was observed during rod seating and report the technical modification used to reduce this displacement. Among 28 patients with acute type II odontoid fractures treated surgically during the study period, 5 patients demonstrated intraoperative posterior odontoid fragment migration during posterior C1 lateral mass–C2 pars screw fixation and were included in this technical case series. Intraoperative lateral fluoroscopy was used to document odontoid fragment position after screw placement, after straight rod seating, and after rod contouring and tightening. Posterior fragment displacement was measured and compared descriptively. Mean posterior odontoid fragment displacement increased from 1.0 ± 0.82 mm before rod placement to a maximum of 4.0 ± 0.82 mm after straight rod seating in extension. After loosening the construct and contouring the rods to better match native C1–C2 sagittal alignment, posterior displacement decreased to 1.0 ± 0.82 mm. Alignment was maintained in all patients at 3-month follow-up, with improvement in mean Nurick grade from 4.2 ± 0.84 to 2.4 ± 0.55. In this small technical case series, straight rod seating was temporally associated with posterior migration of the mobile odontoid fragment during posterior C1–C2 fixation for acute type II odontoid fractures. Careful rod contouring, staged tightening, and continuous lateral fluoroscopic monitoring may help minimize unintended translational forces and allow early recognition of potential canal compromise.

Authors

Institutions

Publication Details

Journal
Asian Journal of Neurosurgery
Published
2026-10-13
DOI
https://doi.org/10.1055/s-0046-1829444
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intraoperative Posterior Migration of the Odontoid Fragment During Posterior C1–C2 Screw–Rod Fixation for Acute Type II Dens Fractures: A Technical Case Series

Awdhesh Yadav, Jason Golmei, Bal Krishna Ojha, Chandra Anil et al.
Asian Journal of Neurosurgery
Spinal Fractures and Fixation Techniques
article

Intraoperative Posterior Migration of the Odontoid Fragment During Posterior C1–C2 Screw–Rod Fixation for Acute Type II Dens Fractures: A Technical Case Series

Awdhesh Yadav, Jason Golmei, Bal Krishna Ojha, Chandra Anil, Hanuman Prasad, Pankaj Pawar
article en

Abstract

Abstract Posterior C1–C2 screw–rod fixation is a well-established treatment for unstable type II odontoid fractures. Although these constructs allow controlled reduction in atlantoaxial pathology, their effect on the mobile odontoid fragment during acute type II dens fracture fixation remains insufficiently described. We describe a series of patients in whom intraoperative posterior migration of the odontoid fragment was observed during rod seating and report the technical modification used to reduce this displacement. Among 28 patients with acute type II odontoid fractures treated surgically during the study period, 5 patients demonstrated intraoperative posterior odontoid fragment migration during posterior C1 lateral mass–C2 pars screw fixation and were included in this technical case series. Intraoperative lateral fluoroscopy was used to document odontoid fragment position after screw placement, after straight rod seating, and after rod contouring and tightening. Posterior fragment displacement was measured and compared descriptively. Mean posterior odontoid fragment displacement increased from 1.0 ± 0.82 mm before rod placement to a maximum of 4.0 ± 0.82 mm after straight rod seating in extension. After loosening the construct and contouring the rods to better match native C1–C2 sagittal alignment, posterior displacement decreased to 1.0 ± 0.82 mm. Alignment was maintained in all patients at 3-month follow-up, with improvement in mean Nurick grade from 4.2 ± 0.84 to 2.4 ± 0.55. In this small technical case series, straight rod seating was temporally associated with posterior migration of the mobile odontoid fragment during posterior C1–C2 fixation for acute type II odontoid fractures. Careful rod contouring, staged tightening, and continuous lateral fluoroscopic monitoring may help minimize unintended translational forces and allow early recognition of potential canal compromise.

Asian Journal of Neurosurgery
King George's Medical University (IN)
Openalex Percentile: Top 10%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.