Optimized Switching-Frequency Control for Improved Efficiency in Three-Phase Isolated Y-Rectifiers

The single-stage three-phase isolated Y-rectifier (iYR) merges power-factor correction and galvanic isolation into two conventional B6 bridges. Its power is conventionally regulated by the phase-shift angle alone at a fixed switching frequency. At light load, the transformer current then forms high-peak pulses whose rms value is large relative to the transferred power, and the efficiency falls. This paper proposes a hybrid phase-shift and variable-frequency control that raises the switching frequency as the load falls, without altering the internal space-vector timings. At the lightest tested load, about 300W, the measured rms current falls by roughly 50 when the frequency is raised from 25kHz to 80kHz. The loss-optimal frequency is identified from hardware measurements rather than from simulation, and is stored as a two-dimensional look-up table indexed on the power reference and the dc output voltage. The strategy is validated on a 3kW prototype over a 350V–450V dc-bus range and a 25kHz–80kHz frequency range. At 400V and 300W, the measured loss falls by 38.6, raising the efficiency from 85.1 to 90.3 . Two transformer designs differing only in the magnetizing inductance are compared, which sets the frequency range over which the strategy reduces the loss.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-10-13
DOI
https://doi.org/10.3390/en19204845
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized Switching-Frequency Control for Improved Efficiency in Three-Phase Isolated Y-Rectifiers

Paolo Mattavelli, Khan Mohammed, Ahmed Y. Farag
Energies
Advanced DC-DC Converters
article

Optimized Switching-Frequency Control for Improved Efficiency in Three-Phase Isolated Y-Rectifiers

Paolo Mattavelli, Khan Mohammed, Ahmed Y. Farag
article en

Abstract

The single-stage three-phase isolated Y-rectifier (iYR) merges power-factor correction and galvanic isolation into two conventional B6 bridges. Its power is conventionally regulated by the phase-shift angle alone at a fixed switching frequency. At light load, the transformer current then forms high-peak pulses whose rms value is large relative to the transferred power, and the efficiency falls. This paper proposes a hybrid phase-shift and variable-frequency control that raises the switching frequency as the load falls, without altering the internal space-vector timings. At the lightest tested load, about 300W, the measured rms current falls by roughly 50 when the frequency is raised from 25kHz to 80kHz. The loss-optimal frequency is identified from hardware measurements rather than from simulation, and is stored as a two-dimensional look-up table indexed on the power reference and the dc output voltage. The strategy is validated on a 3kW prototype over a 350V–450V dc-bus range and a 25kHz–80kHz frequency range. At 400V and 300W, the measured loss falls by 38.6, raising the efficiency from 85.1 to 90.3 . Two transformer designs differing only in the magnetizing inductance are compared, which sets the frequency range over which the strategy reduces the loss.

EnergiesVol. 19(20)
University of Padua (IT)
Openalex Percentile: Top 24%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.