Cyber-Resilient Digital Twin Architectures for Smart Grids: A Review of Attack Modeling, Detection, Mitigation, and Secure Control Strategies

The digitalization of smart grids has expanded the cyberattack surface of critical energy infrastructure, creating a need for security mechanisms that integrate communication behavior, physical-system dynamics, and resilient control. Digital twins provide a promising foundation for this integration, but existing research remains fragmented across system architectures, threat models, defense methods, and validation environments. The aim of this review is to identify, classify, and critically compare how cyber-resilient DT architectures support the smart-grid cybersecurity lifecycle across DT architecture, cyber–physical attack modeling, detection and mitigation, secure control and recovery, and experimental validation. A structured multi-database search of Scopus, IEEE Xplore, and the ACM Digital Library identified 1627 records. After duplicate removal, publication-type exclusions, and eligibility assessment, 149 publications were retained for thematic synthesis and quality appraisal. The evidence indicates that a qualifying cyber-resilient digital twin is distinguished not merely by the presence of a virtual model, but by bidirectional physical–virtual synchronization combined with explicit cyber-resilience functions. Cyberattack studies span measurement, communication, control, device and infrastructure, and coordinated attack surfaces, although study-specific assumptions regarding attacker access and compromised interfaces frequently limit direct comparison. Physics-based detectors offer strong interpretability and real-time suitability but remain sensitive to model and topology errors, whereas data-driven methods capture complex attack patterns but depend on representative data and may generalize poorly. Federated learning preserves data locality but introduces privacy, poisoning, and communication concerns, while moving target defense and deception provide complementary proactive capabilities. No detection or mitigation strategy is uniformly superior across attack coverage, interpretability, false-alarm behavior, latency, scalability, and computational burden. DT-enabled secure control and self-healing further require safety-constrained mitigation under detection uncertainty, communication delay, model mismatch, and partially compromised information. Validation is dominated by simulation, with comparatively little hardware-in-the-loop (HIL) or utility-scale field evidence. Key research gaps include inconsistent digital twin terminology, limited benchmark datasets, synchronization and model-fidelity challenges, inadequate interoperability, and insufficient validation of autonomous mitigation. This review contributes an integrated taxonomy and decision-oriented framework for evaluating and selecting cyber-resilient digital twin strategies for smart grids.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-10-13
DOI
https://doi.org/10.3390/electronics15204701
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cyber-Resilient Digital Twin Architectures for Smart Grids: A Review of Attack Modeling, Detection, Mitigation, and Secure Control Strategies

Suman Rath, Osasumwen Cedric Ogiesoba-Eguakun
Electronics
Smart Grid Security and Resilience
article

Cyber-Resilient Digital Twin Architectures for Smart Grids: A Review of Attack Modeling, Detection, Mitigation, and Secure Control Strategies

Suman Rath, Osasumwen Cedric Ogiesoba-Eguakun
article en

Abstract

The digitalization of smart grids has expanded the cyberattack surface of critical energy infrastructure, creating a need for security mechanisms that integrate communication behavior, physical-system dynamics, and resilient control. Digital twins provide a promising foundation for this integration, but existing research remains fragmented across system architectures, threat models, defense methods, and validation environments. The aim of this review is to identify, classify, and critically compare how cyber-resilient DT architectures support the smart-grid cybersecurity lifecycle across DT architecture, cyber–physical attack modeling, detection and mitigation, secure control and recovery, and experimental validation. A structured multi-database search of Scopus, IEEE Xplore, and the ACM Digital Library identified 1627 records. After duplicate removal, publication-type exclusions, and eligibility assessment, 149 publications were retained for thematic synthesis and quality appraisal. The evidence indicates that a qualifying cyber-resilient digital twin is distinguished not merely by the presence of a virtual model, but by bidirectional physical–virtual synchronization combined with explicit cyber-resilience functions. Cyberattack studies span measurement, communication, control, device and infrastructure, and coordinated attack surfaces, although study-specific assumptions regarding attacker access and compromised interfaces frequently limit direct comparison. Physics-based detectors offer strong interpretability and real-time suitability but remain sensitive to model and topology errors, whereas data-driven methods capture complex attack patterns but depend on representative data and may generalize poorly. Federated learning preserves data locality but introduces privacy, poisoning, and communication concerns, while moving target defense and deception provide complementary proactive capabilities. No detection or mitigation strategy is uniformly superior across attack coverage, interpretability, false-alarm behavior, latency, scalability, and computational burden. DT-enabled secure control and self-healing further require safety-constrained mitigation under detection uncertainty, communication delay, model mismatch, and partially compromised information. Validation is dominated by simulation, with comparatively little hardware-in-the-loop (HIL) or utility-scale field evidence. Key research gaps include inconsistent digital twin terminology, limited benchmark datasets, synchronization and model-fidelity challenges, inadequate interoperability, and insufficient validation of autonomous mitigation. This review contributes an integrated taxonomy and decision-oriented framework for evaluating and selecting cyber-resilient digital twin strategies for smart grids.

ElectronicsVol. 15(20)
University of Tulsa (US)
Openalex Percentile: Top 17%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.