Variability in Refractive Measurements in Children with Autism Spectrum Disorder Under Cycloplegic and Non-Cycloplegic Conditions: Influence of Measurement Method

Purpose: To compare refractive measurements obtained with Retinomax K-plus 3 and Plusoptix A09 V in children with autism spectrum disorder (ASD) before and after cycloplegia and to assess inter-device agreement. Methods: This retrospective pilot study included 23 children with ASD (mean age 6.54 ± 2.83 years), of whom 14 underwent examination with two autorefractometers (Retinomax K-plus 3 and Plusoptix A09 V) before and after cycloplegia induced with 1% tropicamide. Direct inter-device comparisons were restricted to the 14 children with paired measurements and were performed using the Wilcoxon signed-rank test, with matched-pairs rank-biserial correlations reported as effect sizes. Agreement in spherical equivalent (SE) was assessed using Bland–Altman analysis. Cycloplegia-induced refractive shifts were compared between devices. Secondary comparisons with controls without documented neurodevelopmental disorders (n = 27) were restricted to Retinomax SE measurements and performed using analysis of covariance (ANCOVA), with age included as a continuous covariate. Results: Before cycloplegia, Retinomax showed significantly more myopic SE values than Plusoptix in both eyes (right eye [OD]: −1.21 ± 1.25 vs. 0.91 ± 0.67 D; left eye [OS]: −1.22 ± 1.15 vs. 0.77 ± 0.51 D; both p < 0.00417). Significant inter-device differences in SE persisted after cycloplegia (OD: 0.63 ± 0.94 vs. 2.00 ± 0.63 D; OS: 0.46 ± 0.96 vs. 1.98 ± 0.63 D; both p < 0.001). Bland–Altman analysis showed a systematic negative bias of Retinomax relative to Plusoptix, which decreased after cycloplegia but persisted (before: −2.12 D for OD and −1.99 D for OS; after: −1.37 D and −1.52 D, respectively). Cycloplegia-induced shifts were greater with Retinomax; however, the between-device differences were not statistically significant after Bonferroni correction. In secondary analyses, age-adjusted Retinomax SE remained significantly lower in the ASD group than in controls without documented neurodevelopmental disorders before and after cycloplegia (all p < 0.001). Conclusions: In this exploratory cohort of children with ASD, Retinomax measurements were associated with more myopic SE values than Plusoptix, particularly before cycloplegia. The inter-device bias decreased but persisted after cycloplegia. This reduction is compatible with a contribution of accommodation; however, the persistence of the bias after cycloplegia indicates that device-specific measurement characteristics should also be considered. Refractive measurements obtained with the two autorefractometers should therefore not be assumed to be directly interchangeable. These findings underscore the importance of cycloplegic control and careful interpretation of autorefractor measurements in children with ASD. Larger prospective studies are warranted.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-10-13
DOI
https://doi.org/10.3390/jcm15207889
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Variability in Refractive Measurements in Children with Autism Spectrum Disorder Under Cycloplegic and Non-Cycloplegic Conditions: Influence of Measurement Method

Wilhelm Grzesiak, Karolina Skonieczna‐Żydecka, Wiktoria Bosy-Gąsior, Monika Modrzejewska et al.
Journal of Clinical Medicine
Ophthalmology and Visual Impairment Studies
article

Variability in Refractive Measurements in Children with Autism Spectrum Disorder Under Cycloplegic and Non-Cycloplegic Conditions: Influence of Measurement Method

Wilhelm Grzesiak, Karolina Skonieczna‐Żydecka, Wiktoria Bosy-Gąsior, Monika Modrzejewska, Anna Modrzejewska, Oliwia Zdanowska, Piotr Połubiński
article en

Abstract

Purpose: To compare refractive measurements obtained with Retinomax K-plus 3 and Plusoptix A09 V in children with autism spectrum disorder (ASD) before and after cycloplegia and to assess inter-device agreement. Methods: This retrospective pilot study included 23 children with ASD (mean age 6.54 ± 2.83 years), of whom 14 underwent examination with two autorefractometers (Retinomax K-plus 3 and Plusoptix A09 V) before and after cycloplegia induced with 1% tropicamide. Direct inter-device comparisons were restricted to the 14 children with paired measurements and were performed using the Wilcoxon signed-rank test, with matched-pairs rank-biserial correlations reported as effect sizes. Agreement in spherical equivalent (SE) was assessed using Bland–Altman analysis. Cycloplegia-induced refractive shifts were compared between devices. Secondary comparisons with controls without documented neurodevelopmental disorders (n = 27) were restricted to Retinomax SE measurements and performed using analysis of covariance (ANCOVA), with age included as a continuous covariate. Results: Before cycloplegia, Retinomax showed significantly more myopic SE values than Plusoptix in both eyes (right eye [OD]: −1.21 ± 1.25 vs. 0.91 ± 0.67 D; left eye [OS]: −1.22 ± 1.15 vs. 0.77 ± 0.51 D; both p < 0.00417). Significant inter-device differences in SE persisted after cycloplegia (OD: 0.63 ± 0.94 vs. 2.00 ± 0.63 D; OS: 0.46 ± 0.96 vs. 1.98 ± 0.63 D; both p < 0.001). Bland–Altman analysis showed a systematic negative bias of Retinomax relative to Plusoptix, which decreased after cycloplegia but persisted (before: −2.12 D for OD and −1.99 D for OS; after: −1.37 D and −1.52 D, respectively). Cycloplegia-induced shifts were greater with Retinomax; however, the between-device differences were not statistically significant after Bonferroni correction. In secondary analyses, age-adjusted Retinomax SE remained significantly lower in the ASD group than in controls without documented neurodevelopmental disorders before and after cycloplegia (all p < 0.001). Conclusions: In this exploratory cohort of children with ASD, Retinomax measurements were associated with more myopic SE values than Plusoptix, particularly before cycloplegia. The inter-device bias decreased but persisted after cycloplegia. This reduction is compatible with a contribution of accommodation; however, the persistence of the bias after cycloplegia indicates that device-specific measurement characteristics should also be considered. Refractive measurements obtained with the two autorefractometers should therefore not be assumed to be directly interchangeable. These findings underscore the importance of cycloplegic control and careful interpretation of autorefractor measurements in children with ASD. Larger prospective studies are warranted.

Journal of Clinical MedicineVol. 15(20)
West Pomeranian University of Technology in Szczecin (PL), Pomeranian Medical University (PL)
Openalex Percentile: Top 13%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.