Adaptive pulsatile aspiration leads to improved thrombectomy outcomes during in vivo large vessel occlusion for acute ischemic stroke

Background Mechanical thrombectomy is the standard of care for large vessel occlusion (LVO) stroke, with current aspiration systems relying predominantly on static negative pressure for clot retrieval. Adaptive pulsatile aspiration (APA; ALGO smart pump, Von Vascular, Florida, USA) represents a novel non-static approach with promising in vitro results. In this study, we evaluated its in vivo reproducibility in a preclinical model. Methods Thrombectomies were performed using moderate and firm clot analogs in a swine carotid artery LVO model. Static aspiration (Penumbra ENGINE) was compared with APA across 40 procedures (30 APA and 10 static). Primary endpoints were complete clot ingestion (CCI), first pass effect (FPE), successful revascularization (Thrombolysis in Cerebral Infarction (TICI) score ≥2B), and distal embolization. Arterial wall histology was assessed by quantitative injury and endothelial denudation scoring. Results Overall rates were 82.5% successful revascularization, 72.5% CCI, and 70% FPE. CCI was associated with zero distal embolization versus 36.4% in cases with incomplete ingestion (P=0.004). APA was associated with higher rates than static aspiration across all endpoints: revascularization (90% vs 60%), CCI (83.3% vs 40%; P=0.014), FPE (80% vs 40%; P=0.041), and distal embolization (0% vs 40%; P=0.002). In subset analysis, a smaller bore catheter with APA outperformed a larger bore catheter with static aspiration, achieving TICI 3 and CCI in 80% versus 40% of cases. Histology revealed no excess vascular injury attributable to APA. Conclusions APA demonstrated higher rates of complete clot removal, revascularization, and first pass success than static aspiration, with a favorable safety profile. These findings support further clinical evaluation of waveform modulated aspiration strategies in human trials.

Authors

Institutions

Publication Details

Journal
Journal of NeuroInterventional Surgery
Published
2026-10-13
DOI
https://doi.org/10.1136/jnis-2026-025650
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive pulsatile aspiration leads to improved thrombectomy outcomes during in vivo large vessel occlusion for acute ischemic stroke

Nadia McMillan, Joshua Hanna, Sai Sanikommu, Jayro Toledo et al.
Journal of NeuroInterventional Surgery
Acute Ischemic Stroke Management
article

Adaptive pulsatile aspiration leads to improved thrombectomy outcomes during in vivo large vessel occlusion for acute ischemic stroke

Nadia McMillan, Joshua Hanna, Sai Sanikommu, Jayro Toledo, Pedro Bartkevitch Rodrigues, Ahmed Abdelsalam, John Thompson, Robert M Starke
article en

Abstract

Background Mechanical thrombectomy is the standard of care for large vessel occlusion (LVO) stroke, with current aspiration systems relying predominantly on static negative pressure for clot retrieval. Adaptive pulsatile aspiration (APA; ALGO smart pump, Von Vascular, Florida, USA) represents a novel non-static approach with promising in vitro results. In this study, we evaluated its in vivo reproducibility in a preclinical model. Methods Thrombectomies were performed using moderate and firm clot analogs in a swine carotid artery LVO model. Static aspiration (Penumbra ENGINE) was compared with APA across 40 procedures (30 APA and 10 static). Primary endpoints were complete clot ingestion (CCI), first pass effect (FPE), successful revascularization (Thrombolysis in Cerebral Infarction (TICI) score ≥2B), and distal embolization. Arterial wall histology was assessed by quantitative injury and endothelial denudation scoring. Results Overall rates were 82.5% successful revascularization, 72.5% CCI, and 70% FPE. CCI was associated with zero distal embolization versus 36.4% in cases with incomplete ingestion (P=0.004). APA was associated with higher rates than static aspiration across all endpoints: revascularization (90% vs 60%), CCI (83.3% vs 40%; P=0.014), FPE (80% vs 40%; P=0.041), and distal embolization (0% vs 40%; P=0.002). In subset analysis, a smaller bore catheter with APA outperformed a larger bore catheter with static aspiration, achieving TICI 3 and CCI in 80% versus 40% of cases. Histology revealed no excess vascular injury attributable to APA. Conclusions APA demonstrated higher rates of complete clot removal, revascularization, and first pass success than static aspiration, with a favorable safety profile. These findings support further clinical evaluation of waveform modulated aspiration strategies in human trials.

Journal of NeuroInterventional Surgery
University of Miami (US)
Joe Niekro Foundation, Brain Aneurysm Foundation, Bee Foundation
Openalex Percentile: Top 13%
Acute Ischemic Stroke Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.