3D Seepage, Deformation, and Stability Analysis of the Yecha Concrete-Face Rockfill Dam Considering Defect Scenarios

Concrete-face rockfill dams (CFRDs) constructed in narrow valleys and on spatially heterogeneous foundations may experience nonuniform seepage and deformation, while local defects in the seepage-control system can further affect their operational safety. This study establishes a three-dimensional finite element model of the 90 m-high Yecha CFRD to systematically evaluate seepage behavior, stress–deformation response, face slab performance, and slope stability under normal, extreme-water-level, and representative defect scenarios. The seepage analysis considers different reservoir levels as well as peripheral-joint failure, face slab cracking at different elevations, and grout-curtain degradation, while the nonlinear mechanical behavior of the rockfill is described using the Duncan–Chang E–B model with parameters obtained from large-scale triaxial tests. Under normal storage, the seepage-control system remains effective, with a total seepage discharge of 3240.18 m3/d. The maximum dam settlement is 25.15 cm, corresponding to 0.279% of the dam height, and the slope safety factor is 1.48. Low-elevation face slab cracking is identified as a critical local seepage scenario, increasing the hydraulic gradient in the cushion material to 3.39, above the allowable value of 0.45. In addition, a 20% reduction in the mechanical parameters of the main rockfill zones increases the maximum settlement and face slab deflection by 84% and 74%, respectively, indicating a pronounced sensitivity to rockfill mechanical properties. Under the check flood level, the minimum slope safety factor decreases to 1.39 but remains above the code requirement. These results highlight low-elevation face slab integrity and rockfill compaction quality as key factors governing the seepage and deformation safety of CFRDs and provide a practical basis for defect-oriented monitoring and safety assessment.

Authors

Institutions

Publication Details

Journal
Water
Published
2026-10-12
DOI
https://doi.org/10.3390/w18202529
Primary Topic
Dam Engineering and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D Seepage, Deformation, and Stability Analysis of the Yecha Concrete-Face Rockfill Dam Considering Defect Scenarios

Suifeng Wang, Tao Xia, Tao Li, Shuai Wang et al.
Water
Dam Engineering and Safety
article

3D Seepage, Deformation, and Stability Analysis of the Yecha Concrete-Face Rockfill Dam Considering Defect Scenarios

Suifeng Wang, Tao Xia, Tao Li, Shuai Wang, Zhengjun He, Yan Zhang
article en

Abstract

Concrete-face rockfill dams (CFRDs) constructed in narrow valleys and on spatially heterogeneous foundations may experience nonuniform seepage and deformation, while local defects in the seepage-control system can further affect their operational safety. This study establishes a three-dimensional finite element model of the 90 m-high Yecha CFRD to systematically evaluate seepage behavior, stress–deformation response, face slab performance, and slope stability under normal, extreme-water-level, and representative defect scenarios. The seepage analysis considers different reservoir levels as well as peripheral-joint failure, face slab cracking at different elevations, and grout-curtain degradation, while the nonlinear mechanical behavior of the rockfill is described using the Duncan–Chang E–B model with parameters obtained from large-scale triaxial tests. Under normal storage, the seepage-control system remains effective, with a total seepage discharge of 3240.18 m3/d. The maximum dam settlement is 25.15 cm, corresponding to 0.279% of the dam height, and the slope safety factor is 1.48. Low-elevation face slab cracking is identified as a critical local seepage scenario, increasing the hydraulic gradient in the cushion material to 3.39, above the allowable value of 0.45. In addition, a 20% reduction in the mechanical parameters of the main rockfill zones increases the maximum settlement and face slab deflection by 84% and 74%, respectively, indicating a pronounced sensitivity to rockfill mechanical properties. Under the check flood level, the minimum slope safety factor decreases to 1.39 but remains above the code requirement. These results highlight low-elevation face slab integrity and rockfill compaction quality as key factors governing the seepage and deformation safety of CFRDs and provide a practical basis for defect-oriented monitoring and safety assessment.

WaterVol. 18(20)
Wuhan University (CN)
Openalex Percentile: Top 18%
Dam Engineering and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.