Evaluating Analytical Performance of Commercial Screen-Printed Electrodes for Point-of-Care Uric Acid Sensing: A Comparative Study

Uric acid (UA), a key purine metabolite associated with metabolic, cardiovascular, and renal disorders, has been extensively investigated using electrochemical sensors. Increasing efforts now focus on translating these technologies into commercial point-of-care (POC) platforms for rapid, decentralized detection. Commercial screen-printed electrodes (SPEs) are widely employed as substrates for such platforms, typically after surface modification with nanomaterials or recognition elements; however, their inherent, unmodified analytical capabilities remain largely uncharacterized. This gap is significant, as the baseline performance of the underlying electrode ultimately constrains or enables the benefits of any subsequent modification. Here, we systematically compare two commercially available SPEs, DRP-110 and DRP-150, for UA detection using differential pulse voltammetry under standardized conditions. Both electrodes exhibited two distinct UA oxidation peaks. The first peak gave linear calibration over 0.02–0.5 µM (R2 = 0.9863 DRP-110, 0.9928 DRP-150), with validated LOD/LOQ of 0.076/0.230 µM (DRP-110) and 0.055/0.166 µM (DRP-150); the second peak extended the linear working range to 1–1000 µM (DRP-110, R2 = 0.9833) and 1–2000 µM (DRP-150, R2 = 0.9928), with LOD/LOQ of 3.37/10.20 µM and 2.23/6.77 µM, respectively, derived from its low-concentration segment. DRP-150 demonstrated superior sensitivity at both peaks. However, both electrodes showed low selectivity toward ascorbic acid. Spike recovery testing in modified artificial urine gave recoveries of 68.0–98.49%, supporting preliminary feasibility in a defined urine-like matrix.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-10-12
DOI
https://doi.org/10.3390/app162010077
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Analytical Performance of Commercial Screen-Printed Electrodes for Point-of-Care Uric Acid Sensing: A Comparative Study

Ovidiu Gabriel Bratu, Ligia Chelmea, Radu Dan Necula, Sehrish Bilal et al.
Applied Sciences
Electrochemical sensors and biosensors
article

Evaluating Analytical Performance of Commercial Screen-Printed Electrodes for Point-of-Care Uric Acid Sensing: A Comparative Study

Ovidiu Gabriel Bratu, Ligia Chelmea, Radu Dan Necula, Sehrish Bilal, Maria Elena Cocuz, Mihaela Badea, Ioan Scârneciu, Davide Calin Mereu, Andrea Elena Neculau
article en

Abstract

Uric acid (UA), a key purine metabolite associated with metabolic, cardiovascular, and renal disorders, has been extensively investigated using electrochemical sensors. Increasing efforts now focus on translating these technologies into commercial point-of-care (POC) platforms for rapid, decentralized detection. Commercial screen-printed electrodes (SPEs) are widely employed as substrates for such platforms, typically after surface modification with nanomaterials or recognition elements; however, their inherent, unmodified analytical capabilities remain largely uncharacterized. This gap is significant, as the baseline performance of the underlying electrode ultimately constrains or enables the benefits of any subsequent modification. Here, we systematically compare two commercially available SPEs, DRP-110 and DRP-150, for UA detection using differential pulse voltammetry under standardized conditions. Both electrodes exhibited two distinct UA oxidation peaks. The first peak gave linear calibration over 0.02–0.5 µM (R2 = 0.9863 DRP-110, 0.9928 DRP-150), with validated LOD/LOQ of 0.076/0.230 µM (DRP-110) and 0.055/0.166 µM (DRP-150); the second peak extended the linear working range to 1–1000 µM (DRP-110, R2 = 0.9833) and 1–2000 µM (DRP-150, R2 = 0.9928), with LOD/LOQ of 3.37/10.20 µM and 2.23/6.77 µM, respectively, derived from its low-concentration segment. DRP-150 demonstrated superior sensitivity at both peaks. However, both electrodes showed low selectivity toward ascorbic acid. Spike recovery testing in modified artificial urine gave recoveries of 68.0–98.49%, supporting preliminary feasibility in a defined urine-like matrix.

Applied SciencesVol. 16(20)
Carol Davila University of Medicine and Pharmacy (RO), Clinical Emergency Hospital Bucharest (RO), Transylvania University of Brașov (RO), Emergency University (US), Fundaţia pentru Formare Profesională şi Învăţământ Preuniversitar - Viitor (RO)
Openalex Percentile: Top 23%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.