Highly Sensitive Determination of Tiamulin in Meat Products by Lateral Flow Immunoassay with Magnetic Preconcentration

Background: Magnetic particles are a unique marker for immunochromatographic test systems, enabling the concentration of the analyte from large-volume samples. The proposed test systems differ in the markers used (gold nanoparticles and magnetic particles) and the analysis format (direct and indirect marker introduction into the analytical zone). Method: The most effective test system is based on the use of magnetic particles as a carrier of specific anti-bodies, followed by colorimetric detection of the analytical signal by introducing a colloidal gold conjugate with anti-species antibodies. Results: For the developed test system, a visual detection limit of 0.13 ng/mL and an instrumental detection limit of 89 pg/mL (27 pg/mL with concentration) were achieved. Enhancement with colloidal gold allowed us to reduce detection limits by 11 times, and preliminary concentration by up to 37 times. The feasibility of applying the approach to preconcentration of tiamulin from real food matrices (chicken, beef, and egg) is demonstrated. The analyte detection rate was 94–108%.

Authors

Institutions

Publication Details

Journal
Antibiotics
Published
2026-11-26
DOI
https://doi.org/10.3390/antibiotics15121184
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Highly Sensitive Determination of Tiamulin in Meat Products by Lateral Flow Immunoassay with Magnetic Preconcentration

Е. А. Зверева, Boris Borisovich Dzantiev, Alisa A. Bulanaya, Nadezhda A. Taranova et al.
1 links
Antibiotics
Biosensors and Analytical Detection
article

Highly Sensitive Determination of Tiamulin in Meat Products by Lateral Flow Immunoassay with Magnetic Preconcentration

Е. А. Зверева, Boris Borisovich Dzantiev, Alisa A. Bulanaya, Nadezhda A. Taranova, Angelina A. Aslamova, Anatoly V. Zherdev
article en

Abstract

Background: Magnetic particles are a unique marker for immunochromatographic test systems, enabling the concentration of the analyte from large-volume samples. The proposed test systems differ in the markers used (gold nanoparticles and magnetic particles) and the analysis format (direct and indirect marker introduction into the analytical zone). Method: The most effective test system is based on the use of magnetic particles as a carrier of specific anti-bodies, followed by colorimetric detection of the analytical signal by introducing a colloidal gold conjugate with anti-species antibodies. Results: For the developed test system, a visual detection limit of 0.13 ng/mL and an instrumental detection limit of 89 pg/mL (27 pg/mL with concentration) were achieved. Enhancement with colloidal gold allowed us to reduce detection limits by 11 times, and preliminary concentration by up to 37 times. The feasibility of applying the approach to preconcentration of tiamulin from real food matrices (chicken, beef, and egg) is demonstrated. The analyte detection rate was 94–108%.

AntibioticsVol. 15(12)
Russian Academy of Sciences (RU), Federal Research Centre «Fundamentals of Biotechnology» of the Russian Academy of Sciences (RU)
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon