Fewer poor joint awareness results with cementless TKA compared with the same-design cemented implant

Abstract Background Comparisons of cemented and cementless TKA have focused on mean outcomes and generally reported equivalence. We hypothesized that a 3D-printed full-titanium cementless TKA and the same-design cemented implant would not differ significantly in average joint awareness but would differ in the proportion of patients with the poorest results, and we compared the two both at the mean and across the outcome distribution. Methods Prospective two-cohort study of 109 primary unilateral TKAs (54 cementless, 55 cemented) for end-stage knee osteoarthritis, with complete 24-month follow-up. Exclusion criteria were valgus deformity and bilateral surgery. The primary outcome was the FJS-12, analysed both at the mean (multivariable linear regression, with propensity score overlap weighting as sensitivity analysis) and across its distribution (quantile regression). Secondary outcomes were PASS achievement (FJS-12 ≥ 33.3), OKS, and time to functional satisfaction. Results The cementless group was younger ( P < 0.001) with more men ( P = 0.008). Mean FJS-12 was not different between groups after adjustment (β = 7.4, 95% CI − 1.8 to 16.6, P = 0.115), although the confidence interval did not exclude a difference exceeding the minimal clinically important difference; this finding was reproduced by overlap weighting. On quantile regression, cementless patients scored significantly higher at the 10th and 25th percentiles (adjusted P = 0.028 and 0.021) but not at the median or above. A greater proportion of cementless patients achieved the PASS (96.3% vs. 76.4%; absolute difference 19.9%, 95% CI 7.1 to 32.9; number needed to treat 5), which persisted after adjustment ( P = 0.005). No significant differences were observed in OKS ( P = 0.91) or time to functional satisfaction (adjusted P = 0.39). No revisions or loosening occurred. Conclusion The 3D-printed full-titanium cementless TKA did not produce a significantly higher mean FJS-12 than the same-design cemented device at 24 months, but it significantly reduced the proportion of patients with poor joint awareness outcomes. Level of evidence III.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2026-10-09
DOI
https://doi.org/10.1007/s00402-026-06531-w
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fewer poor joint awareness results with cementless TKA compared with the same-design cemented implant

Andrea Baldini, Paolo Salari, Luca De Berardinis, Filippo Leggieri et al.
Archives of Orthopaedic and Trauma Surgery
Total Knee Arthroplasty Outcomes
article

Fewer poor joint awareness results with cementless TKA compared with the same-design cemented implant

Andrea Baldini, Paolo Salari, Luca De Berardinis, Filippo Leggieri, Giuseppe Polizzotti
article en

Abstract

Abstract Background Comparisons of cemented and cementless TKA have focused on mean outcomes and generally reported equivalence. We hypothesized that a 3D-printed full-titanium cementless TKA and the same-design cemented implant would not differ significantly in average joint awareness but would differ in the proportion of patients with the poorest results, and we compared the two both at the mean and across the outcome distribution. Methods Prospective two-cohort study of 109 primary unilateral TKAs (54 cementless, 55 cemented) for end-stage knee osteoarthritis, with complete 24-month follow-up. Exclusion criteria were valgus deformity and bilateral surgery. The primary outcome was the FJS-12, analysed both at the mean (multivariable linear regression, with propensity score overlap weighting as sensitivity analysis) and across its distribution (quantile regression). Secondary outcomes were PASS achievement (FJS-12 ≥ 33.3), OKS, and time to functional satisfaction. Results The cementless group was younger ( P < 0.001) with more men ( P = 0.008). Mean FJS-12 was not different between groups after adjustment (β = 7.4, 95% CI − 1.8 to 16.6, P = 0.115), although the confidence interval did not exclude a difference exceeding the minimal clinically important difference; this finding was reproduced by overlap weighting. On quantile regression, cementless patients scored significantly higher at the 10th and 25th percentiles (adjusted P = 0.028 and 0.021) but not at the median or above. A greater proportion of cementless patients achieved the PASS (96.3% vs. 76.4%; absolute difference 19.9%, 95% CI 7.1 to 32.9; number needed to treat 5), which persisted after adjustment ( P = 0.005). No significant differences were observed in OKS ( P = 0.91) or time to functional satisfaction (adjusted P = 0.39). No revisions or loosening occurred. Conclusion The 3D-printed full-titanium cementless TKA did not produce a significantly higher mean FJS-12 than the same-design cemented device at 24 months, but it significantly reduced the proportion of patients with poor joint awareness outcomes. Level of evidence III.

Archives of Orthopaedic and Trauma SurgeryVol. 146(1)
Paracelsus Medical University (AT), IRCCS Ospedale San Raffaele (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Firenze (IT), University of Florence (IT)
Openalex Percentile: Top 9%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.