Functionalized Cellulose-Based Wearable Textile Detection from Insensible Sweat to a Multiparameter Biomarker in Sensible Sweat

Sweat is a key physiological fluid involved in regulating body temperature and maintaining hydration balance. Compared with sensible sweat, insensible sweat is continuously lost in the form of water vapor. Its dynamic variation is closely associated with skin barrier function and basic thermoregulatory activity. However, its low flux and diffuse distribution make reliable detection challenging. In addition, multiparameter analysis of biochemical components in sensible sweat is of significant importance for the evaluation of electrolyte balance and physiological status. In this work, a multiparameter textile platform based on functionalized cellulose materials was developed for monitoring and analyzing the sweating process. Cellulose was employed as the core material platform. By incorporating lithium chloride, humidity-responsive units were fabricated and further configured into a scalable fabric-integrable array, enabling the detection of subtle humidity variations induced by low-flux insensible sweat. As thermal load increased and the system transitioned to the sensible sweating stage, electrochemical sensing fibers were integrated. In combination with the sweat absorption and transport capability of cellulose yarns, the platform enabled the determination of key biochemical parameters in sensible sweat, including pH, sodium, potassium, and uric acid. On-body sweat analysis demonstrated that the textile system enables array-based monitoring of insensible sweat, during the transition to the sensible sweating stage, allowing simultaneous acquisition of multiple physiological parameters. This integrated capability provides a promising approach for continuous monitoring and evaluation of the human sweat rate, electrolyte balance, and related physiological conditions.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-10-09
DOI
https://doi.org/10.1021/acssensors.6c02772
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Functionalized Cellulose-Based Wearable Textile Detection from Insensible Sweat to a Multiparameter Biomarker in Sensible Sweat

Guoqing Feng, Qingjun Liu, Zhiqing Gao, Fengrong Liu et al.
ACS Sensors
Advanced Sensor and Energy Harvesting Materials
article

Functionalized Cellulose-Based Wearable Textile Detection from Insensible Sweat to a Multiparameter Biomarker in Sensible Sweat

Guoqing Feng, Qingjun Liu, Zhiqing Gao, Fengrong Liu, Feiyang Huang, Yuhang He, Yunrui Cao, Ang Li, Hao Wen
article en

Abstract

Sweat is a key physiological fluid involved in regulating body temperature and maintaining hydration balance. Compared with sensible sweat, insensible sweat is continuously lost in the form of water vapor. Its dynamic variation is closely associated with skin barrier function and basic thermoregulatory activity. However, its low flux and diffuse distribution make reliable detection challenging. In addition, multiparameter analysis of biochemical components in sensible sweat is of significant importance for the evaluation of electrolyte balance and physiological status. In this work, a multiparameter textile platform based on functionalized cellulose materials was developed for monitoring and analyzing the sweating process. Cellulose was employed as the core material platform. By incorporating lithium chloride, humidity-responsive units were fabricated and further configured into a scalable fabric-integrable array, enabling the detection of subtle humidity variations induced by low-flux insensible sweat. As thermal load increased and the system transitioned to the sensible sweating stage, electrochemical sensing fibers were integrated. In combination with the sweat absorption and transport capability of cellulose yarns, the platform enabled the determination of key biochemical parameters in sensible sweat, including pH, sodium, potassium, and uric acid. On-body sweat analysis demonstrated that the textile system enables array-based monitoring of insensible sweat, during the transition to the sensible sweating stage, allowing simultaneous acquisition of multiple physiological parameters. This integrated capability provides a promising approach for continuous monitoring and evaluation of the human sweat rate, electrolyte balance, and related physiological conditions.

ACS Sensors
Wenzhou University (CN), Zhejiang University (CN)
Openalex Percentile: Top 24%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.