Automated CMR Quantification of Pulmonary Artery Size-Based and Slow-Flow Metrics in Pulmonary Hypertension

Background/Objectives: Pulmonary artery (PA) dilatation and slow-flow are imaging features of pulmonary hypertension (PH), but their quantitative assessment on routine cardiovascular magnetic resonance (CMR) remains limited. This study aimed to develop and evaluate an automated CMR pipeline for quantifying PA size-based and slow-flow metrics from routine white-blood (WB) and black-blood (BB) acquisitions. Methods: A total of 205 CMR acquisitions (106 WB and 99 BB) were used for model development and independent testing. Separate deep learning nnU-Net-based segmentation models were developed for WB and BB acquisitions using a two-stage cascaded framework. Automated measurements included PA volume and PA slow-flow. The trained models were subsequently applied to a larger cohort of 1471 patients using available WB and BB acquisitions to assess automated measurement extraction and agreement with clinical reports. Results: Automated PA volumetric measurements demonstrated excellent agreement with manual reference measurements for both the WB and BB models (ICC 0.94 and 0.93, respectively), with high segmentation accuracy (Dice 0.86 and 0.80, respectively). Automated slow-flow measurements also demonstrated excellent volumetric agreement (ICC 0.94), despite lower spatial overlap (Dice 0.61). Automated slow-flow classification demonstrated 83% agreement with qualitative clinical reporting (κ = 0.58). Conclusions: Automated PA volumetric quantification from routine CMR is feasible. Automated slow-flow quantification showed promising performance but requires validation across scanner vendors and BB acquisition protocols before broader clinical application.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-10-08
DOI
https://doi.org/10.3390/diagnostics16193257
Primary Topic
Pulmonary Hypertension Research and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated CMR Quantification of Pulmonary Artery Size-Based and Slow-Flow Metrics in Pulmonary Hypertension

David Gerard Kiely, Smitha Rajaram, Alireza Hokmabadi, Pankaj Garg et al.
Diagnostics
Pulmonary Hypertension Research and Treatments
article

Automated CMR Quantification of Pulmonary Artery Size-Based and Slow-Flow Metrics in Pulmonary Hypertension

David Gerard Kiely, Smitha Rajaram, Alireza Hokmabadi, Pankaj Garg, Turki Alnasser, Rob J. van der Geest, Michael J. Sharkey, Samer Alabed, Khalid Alghamdi, Daniel James Taylor, Andrew J. Swift
article en

Abstract

Background/Objectives: Pulmonary artery (PA) dilatation and slow-flow are imaging features of pulmonary hypertension (PH), but their quantitative assessment on routine cardiovascular magnetic resonance (CMR) remains limited. This study aimed to develop and evaluate an automated CMR pipeline for quantifying PA size-based and slow-flow metrics from routine white-blood (WB) and black-blood (BB) acquisitions. Methods: A total of 205 CMR acquisitions (106 WB and 99 BB) were used for model development and independent testing. Separate deep learning nnU-Net-based segmentation models were developed for WB and BB acquisitions using a two-stage cascaded framework. Automated measurements included PA volume and PA slow-flow. The trained models were subsequently applied to a larger cohort of 1471 patients using available WB and BB acquisitions to assess automated measurement extraction and agreement with clinical reports. Results: Automated PA volumetric measurements demonstrated excellent agreement with manual reference measurements for both the WB and BB models (ICC 0.94 and 0.93, respectively), with high segmentation accuracy (Dice 0.86 and 0.80, respectively). Automated slow-flow measurements also demonstrated excellent volumetric agreement (ICC 0.94), despite lower spatial overlap (Dice 0.61). Automated slow-flow classification demonstrated 83% agreement with qualitative clinical reporting (κ = 0.58). Conclusions: Automated PA volumetric quantification from routine CMR is feasible. Automated slow-flow quantification showed promising performance but requires validation across scanner vendors and BB acquisition protocols before broader clinical application.

DiagnosticsVol. 16(19)
University of East Anglia (GB), King Saud bin Abdulaziz University for Health Sciences (SA), Leiden University Medical Center (NL), National Institute for Health and Care Research (GB), King Abdullah International Medical Research Center (SA), Sheffield Teaching Hospitals NHS Foundation Trust (GB), Insigneo (GB), NIHR Sheffield Biomedical Research Centre (GB), Imam Abdulrahman Bin Faisal University (SA), University of Sheffield (GB)
Openalex Percentile: Top 12%
Pulmonary Hypertension Research and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.