Running style and stability during uphill running are largely preserved with increasing shoe sole thickness

Advanced footwear technology (AFT) shoes incorporate increased sole thickness and compliant midsole materials that may alter running biomechanics. While these effects have been widely studied during level running, little is known about how sole thickness influences running style and stability during uphill running. This study examined the effects of two AFT shoes differing in sole thickness (35 mm-AFT35; 50 mm-AFT50) and a traditional control shoe (27 mm-CON27) on running style and stability during uphill running. Seventeen experienced male runners performed treadmill running at a 10% incline at 6.5 and 10 km/h in three shoe conditions. Running style was assessed using duty factor, normalized step frequency, center-of-mass oscillation, vertical and leg stiffness, and lower-limb joint kinematics. Running stability was evaluated using local dynamic stability via the maximum Lyapunov exponent and detrended fluctuation analysis of stride time. Duty factor and normalized step frequency did not differ between shoes. However, AFT shoes showed greater center-of-mass oscillation (p = 0.004), and lower vertical stiffness (p = 0.022) compared to CON27. Joint kinematics revealed significant shoe effects at the ankle (p = 0.001), particularly increased dorsiflexion and eversion in AFT conditions. Running stability showed only minor changes. Local dynamic stability differed at the trunk (p = 0.027), with reduced stability in AFT50 compared with CON27 (p = 0.006), while global stability remained unchanged. No shoe × speed interactions were observed for any variable. Overall, uphill running style and stability remained largely preserved across shoe conditions, suggesting that sole thickness alone had limited influence.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-10-08
DOI
https://doi.org/10.1371/journal.pone.0348380
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Running style and stability during uphill running are largely preserved with increasing shoe sole thickness

Thorsten Stein, Bernd J. Stetter, Cagla Kettner
PLoS ONE
Lower Extremity Biomechanics and Pathologies
article

Running style and stability during uphill running are largely preserved with increasing shoe sole thickness

Thorsten Stein, Bernd J. Stetter, Cagla Kettner
article en

Abstract

Advanced footwear technology (AFT) shoes incorporate increased sole thickness and compliant midsole materials that may alter running biomechanics. While these effects have been widely studied during level running, little is known about how sole thickness influences running style and stability during uphill running. This study examined the effects of two AFT shoes differing in sole thickness (35 mm-AFT35; 50 mm-AFT50) and a traditional control shoe (27 mm-CON27) on running style and stability during uphill running. Seventeen experienced male runners performed treadmill running at a 10% incline at 6.5 and 10 km/h in three shoe conditions. Running style was assessed using duty factor, normalized step frequency, center-of-mass oscillation, vertical and leg stiffness, and lower-limb joint kinematics. Running stability was evaluated using local dynamic stability via the maximum Lyapunov exponent and detrended fluctuation analysis of stride time. Duty factor and normalized step frequency did not differ between shoes. However, AFT shoes showed greater center-of-mass oscillation (p = 0.004), and lower vertical stiffness (p = 0.022) compared to CON27. Joint kinematics revealed significant shoe effects at the ankle (p = 0.001), particularly increased dorsiflexion and eversion in AFT conditions. Running stability showed only minor changes. Local dynamic stability differed at the trunk (p = 0.027), with reduced stability in AFT50 compared with CON27 (p = 0.006), while global stability remained unchanged. No shoe × speed interactions were observed for any variable. Overall, uphill running style and stability remained largely preserved across shoe conditions, suggesting that sole thickness alone had limited influence.

PLoS ONEVol. 21(10)
Karlsruhe Institute of Technology (DE), Netaji Subhas National Institute of Sports (IN), Institute of Sports Medicine and Science (JP)
Openalex Percentile: Top 24%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.