Optimal Depolarization Sequence for CRT Patients

Abstract Background Electrical ventricular dyssynchrony is a hallmark of intraventricular conduction disease in heart failure with reduced ejection fraction. Although cardiac resynchronization therapy (CRT) is effective, a proportion of patients with ECG evidenced electrical dyssynchrony remain non-responders. Besides the QRS duration, visualization and quantification of the depolarization sequence could contribute to improving CRT response. Objective The study aimed to evaluate the CineECG-derived mean temporo-spatial isochrone trajectory of depolarization in CRT patients. Methods Among the adult cohort of 121 patients who underwent CRT implantation, there were 93 (33% female) responders and 28 (7% female) non-responders. ECGs recorded before and immediately after CRT implantation were collected and analyzed using the CineECG modality with a generic heart/torso model. The CineECG-derived path directions were computed for the QRS on anteroposterior, interventricular, and apicobasal axes within the cardiac anatomy. Spatial depolarization characteristics were tested for the association with left ventricle reverse-remodeling at six-month follow-up. Results The pre-implantation depolarization sequence was predominantly from the right to the left ventricle, and after the CRT implant, it has been transformed into an apicobasal direction. In multivariate logistic regression, the pre-implant QRS duration, apicobasal depolarization gradient, and CRT-induced QRS shortening independently predicted CRT response. The Akaike information criterion indicated that combining all three yielded the strongest predictive model. Conclusion CineECG-derived depolarization gradients, which reflect ventricular activation sequence, changed significantly after CRT, and the pre-implantation apicobasal gradient independently predicted echocardiographic outcome, with a less pronounced gradient associated with better hemodynamic response.

Authors

Institutions

Publication Details

Journal
European Heart Journal Open
Published
2026-10-08
DOI
https://doi.org/10.1093/ehjopen/oeag165
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Depolarization Sequence for CRT Patients

Karol Čurila, Pavel Leinveber, Josef Kautzner, Jan E. Azarov et al.
European Heart Journal Open
Cardiac pacing and defibrillation studies
article

Optimal Depolarization Sequence for CRT Patients

Karol Čurila, Pavel Leinveber, Josef Kautzner, Jan E. Azarov, Peter van Dam, Ksenia A. Sedova
article en

Abstract

Abstract Background Electrical ventricular dyssynchrony is a hallmark of intraventricular conduction disease in heart failure with reduced ejection fraction. Although cardiac resynchronization therapy (CRT) is effective, a proportion of patients with ECG evidenced electrical dyssynchrony remain non-responders. Besides the QRS duration, visualization and quantification of the depolarization sequence could contribute to improving CRT response. Objective The study aimed to evaluate the CineECG-derived mean temporo-spatial isochrone trajectory of depolarization in CRT patients. Methods Among the adult cohort of 121 patients who underwent CRT implantation, there were 93 (33% female) responders and 28 (7% female) non-responders. ECGs recorded before and immediately after CRT implantation were collected and analyzed using the CineECG modality with a generic heart/torso model. The CineECG-derived path directions were computed for the QRS on anteroposterior, interventricular, and apicobasal axes within the cardiac anatomy. Spatial depolarization characteristics were tested for the association with left ventricle reverse-remodeling at six-month follow-up. Results The pre-implantation depolarization sequence was predominantly from the right to the left ventricle, and after the CRT implant, it has been transformed into an apicobasal direction. In multivariate logistic regression, the pre-implant QRS duration, apicobasal depolarization gradient, and CRT-induced QRS shortening independently predicted CRT response. The Akaike information criterion indicated that combining all three yielded the strongest predictive model. Conclusion CineECG-derived depolarization gradients, which reflect ventricular activation sequence, changed significantly after CRT, and the pre-implantation apicobasal gradient independently predicted echocardiographic outcome, with a less pronounced gradient associated with better hemodynamic response.

European Heart Journal Open
Jagiellonian University (PL), Charles University (CZ), International Clinical Research Center, St. Anne's University Hospital Brno (CZ), Institute of Clinical and Experimental Medicine (CZ), University Hospital Kralovske Vinohrady (CZ), Czech Technical University in Prague (CZ)
Openalex Percentile: Top 11%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.