A physiologically constrained calibration framework for cardiovascular models applied to a paediatric synthetic sepsis population

Calibration of mechanistic cardiovascular models is a central barrier to their use in population analysis and patient-specific simulation, particularly in settings where key physiological variables are unobservable and multiple parameter combinations can reproduce the same haemodynamic targets. In this work, we present Embedded Feedback Controller (EFC), a calibration framework for ODE-based lumped-parameter cardiovascular models in which selected physiological parameters are promoted to dynamic states and driven toward prescribed targets through embedded controller equations. By exploiting the qualitative structure of the governing equations, EFC enforces physiologically consistent parameter-variable relationships and converges to the single solution admitted by an over-determined set of targets, reproducibly and independently of the initial conditions, at a cost that scales efficiently with model complexity. The framework is demonstrated in silico, using a mechanistic cardiovascular model to generate virtual paediatric populations spanning normal physiology and two septic shock phenotypes (warm and cold shock) from literature-derived target ranges, achieving <1% residual error across pressures, flows, and compartmental volumes. The resulting parameter distributions are consistent, by construction with theoretical haemodynamic adaptations in paediatric sepsis, including alterations in vascular resistance, compliance, cardiac elastance, and effective blood volume. Importantly, persistent calibration residuals arise when target combinations are structurally incompatible with the model and the parameter carrying the residual is held at a bound, providing an explicit and interpretable diagnostic of feasibility limits. These results establish EFC as a general, scalable calibration strategy for mechanistic cardiovascular models and a practical foundation for virtual population generation and future patient-specific digital twin applications in critical care.

Authors

Institutions

Publication Details

Journal
PLoS Computational Biology
Published
2026-10-07
DOI
https://doi.org/10.1371/journal.pcbi.1014847
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A physiologically constrained calibration framework for cardiovascular models applied to a paediatric synthetic sepsis population

Manuel Teixeira Cabeleira, Vanessa Díaz‐Zuccarini, Nicholas Charles Ovenden, Samiran Ray
PLoS Computational Biology
Sepsis Diagnosis and Treatment
article

A physiologically constrained calibration framework for cardiovascular models applied to a paediatric synthetic sepsis population

Manuel Teixeira Cabeleira, Vanessa Díaz‐Zuccarini, Nicholas Charles Ovenden, Samiran Ray
article en

Abstract

Calibration of mechanistic cardiovascular models is a central barrier to their use in population analysis and patient-specific simulation, particularly in settings where key physiological variables are unobservable and multiple parameter combinations can reproduce the same haemodynamic targets. In this work, we present Embedded Feedback Controller (EFC), a calibration framework for ODE-based lumped-parameter cardiovascular models in which selected physiological parameters are promoted to dynamic states and driven toward prescribed targets through embedded controller equations. By exploiting the qualitative structure of the governing equations, EFC enforces physiologically consistent parameter-variable relationships and converges to the single solution admitted by an over-determined set of targets, reproducibly and independently of the initial conditions, at a cost that scales efficiently with model complexity. The framework is demonstrated in silico, using a mechanistic cardiovascular model to generate virtual paediatric populations spanning normal physiology and two septic shock phenotypes (warm and cold shock) from literature-derived target ranges, achieving <1% residual error across pressures, flows, and compartmental volumes. The resulting parameter distributions are consistent, by construction with theoretical haemodynamic adaptations in paediatric sepsis, including alterations in vascular resistance, compliance, cardiac elastance, and effective blood volume. Importantly, persistent calibration residuals arise when target combinations are structurally incompatible with the model and the parameter carrying the residual is held at a bound, providing an explicit and interpretable diagnostic of feasibility limits. These results establish EFC as a general, scalable calibration strategy for mechanistic cardiovascular models and a practical foundation for virtual population generation and future patient-specific digital twin applications in critical care.

PLoS Computational BiologyVol. 22(10)
Great Ormond Street Hospital (GB), Great Ormond Street Hospital for Children NHS Foundation Trust (GB), University College London (GB)
Openalex Percentile: Top 11%
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.