Comparative evaluation of conventional Machine learning and automated pipeline optimization for MRI radiomics in Hepatocellular carcinoma

Background Hepatocellular carcinoma (HCC) is a prevalent cancer in Malaysia and often detected at advanced stage. Utilisation of automated machine learning (AutoML) with radiomics data reduce reliance on visual interpretation in clinical practice. Aim This study evaluated the performance of conventional Support Vector Machine (SVM) incorporated with Analysis of Variance (ANOVA) F-test and Binary Particle Swarm Optimization (BPSO) and investigated the effect of selected features on the AutoML for differentiating stages of HCC on magnetic resonance imaging (MRI). Methods A total of 662 radiomic features were extracted from the segmented HCC MR images. The proposed conventional model utilised selected features with an optimized SVM classifier. Four AutoML configurations, TPOT-Default, TPOT-LinearSVC, H2O, and AutoGluon were evaluated in two phases: Phase 1 employed the original feature set whereas Phase 2 used the selected subset. Performance was assessed for all nine models using accuracy, precision, recall, specificity, F1-score, area under curve (AUC) and precision-recall curve (PRC). DeLong and McNemar’s tests were employed for pairwise statistical comparisons. Results The conventional model achieved an accuracy of 0.650 and the highest numerical AUC (0.745) and PRC (0.836) among all evaluated models·H2O achieved the highest accuracy (0.700) in both phases. TPOT-LinearSVC showed the greatest improvement after implementation of feature selection, while AutoGluon improved in several threshold-dependent metrics. No pairwise differences were statistically significant (all p > 0.05). Conclusion The proposed feature selection strategy demonstrated a model-dependent effect on the classification performance. Although the conventional model achieved a high AUC and PRC, its performance was not statistically superior to the AutoML models.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-10-07
DOI
https://doi.org/10.1016/j.bspc.2026.111642
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of conventional Machine learning and automated pipeline optimization for MRI radiomics in Hepatocellular carcinoma

Mohammad Johari Ibahim, Mohd Hazeman Zakaria, Nurin Syazwina Mohd Haniff, Muhammad Khalis Abdul Karim et al.
Biomedical Signal Processing and Control
Radiomics and Machine Learning in Medical Imaging
article

Comparative evaluation of conventional Machine learning and automated pipeline optimization for MRI radiomics in Hepatocellular carcinoma

Mohammad Johari Ibahim, Mohd Hazeman Zakaria, Nurin Syazwina Mohd Haniff, Muhammad Khalis Abdul Karim, M.’Aqil Syahiran Izham
article en

Abstract

Background Hepatocellular carcinoma (HCC) is a prevalent cancer in Malaysia and often detected at advanced stage. Utilisation of automated machine learning (AutoML) with radiomics data reduce reliance on visual interpretation in clinical practice. Aim This study evaluated the performance of conventional Support Vector Machine (SVM) incorporated with Analysis of Variance (ANOVA) F-test and Binary Particle Swarm Optimization (BPSO) and investigated the effect of selected features on the AutoML for differentiating stages of HCC on magnetic resonance imaging (MRI). Methods A total of 662 radiomic features were extracted from the segmented HCC MR images. The proposed conventional model utilised selected features with an optimized SVM classifier. Four AutoML configurations, TPOT-Default, TPOT-LinearSVC, H2O, and AutoGluon were evaluated in two phases: Phase 1 employed the original feature set whereas Phase 2 used the selected subset. Performance was assessed for all nine models using accuracy, precision, recall, specificity, F1-score, area under curve (AUC) and precision-recall curve (PRC). DeLong and McNemar’s tests were employed for pairwise statistical comparisons. Results The conventional model achieved an accuracy of 0.650 and the highest numerical AUC (0.745) and PRC (0.836) among all evaluated models·H2O achieved the highest accuracy (0.700) in both phases. TPOT-LinearSVC showed the greatest improvement after implementation of feature selection, while AutoGluon improved in several threshold-dependent metrics. No pairwise differences were statistically significant (all p > 0.05). Conclusion The proposed feature selection strategy demonstrated a model-dependent effect on the classification performance. Although the conventional model achieved a high AUC and PRC, its performance was not statistically superior to the AutoML models.

Biomedical Signal Processing and ControlVol. 130
Universiti Putra Malaysia (MY), Universiti Teknologi MARA (MY)
Openalex Percentile: Top 12%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.