Consensus‐Recommended Follow‐Up Mediates Cardiovascular Outcomes Disparities Between Implantable Cardioverter Defibrillator and Pacemaker Recipients

BACKGROUND: Consensus-recommended follow-up after cardiac implantable electronic device (CIED) implantation improves outcomes, yet whether it mediates cardiovascular disparities between device types remains unknown. METHODS: We prospectively studied 6806 patients undergoing CIED implantation across a multi-hospital system (2019-2023; median follow-up 3.5 years), categorized as implantable cardioverter defibrillator (ICD) (n = 2757) or permanent pacemaker (PPM) (n = 4049). Causal mediation analysis decomposed the effect of device type on major adverse cardiovascular events (MACE) and device extraction into direct and follow-up mediated components, adjusting for demographics and comorbidities. RESULTS: ICD recipients had significantly lower consensus-recommended follow-up rates than PPM recipients (65.3% vs. 79.2%; adjusted OR 0.46, 95% CI 0.40-0.52, p < 0.001) and substantially higher MACE risk (HR 1.89, 95% CI 1.66-2.25, p < 0.001), of which 53.5% was mediated by follow-up adherence. Device extraction rates were lower in ICD recipients (HR 0.30, 95% CI 0.24-0.38), with only 7.9% mediated by follow-up adherence. CONCLUSIONS: More than half of the excess cardiovascular risk in ICD recipients was statistically mediated by suboptimal follow-up adherence-a potentially modifiable pathway. These findings identify follow-up adherence as a potentially important pathway and support further prospective investigation of strategies to improve monitoring and clinical outcomes in high-risk CIED populations.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Electrophysiology
Published
2026-10-06
DOI
https://doi.org/10.1111/jce.70521
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Consensus‐Recommended Follow‐Up Mediates Cardiovascular Outcomes Disparities Between Implantable Cardioverter Defibrillator and Pacemaker Recipients

Michael Shane Lloyd, Chang Liu, Jingwen Huang, Rahul S. Patel
Journal of Cardiovascular Electrophysiology
Cardiac pacing and defibrillation studies
article

Consensus‐Recommended Follow‐Up Mediates Cardiovascular Outcomes Disparities Between Implantable Cardioverter Defibrillator and Pacemaker Recipients

Michael Shane Lloyd, Chang Liu, Jingwen Huang, Rahul S. Patel
article en

Abstract

BACKGROUND: Consensus-recommended follow-up after cardiac implantable electronic device (CIED) implantation improves outcomes, yet whether it mediates cardiovascular disparities between device types remains unknown. METHODS: We prospectively studied 6806 patients undergoing CIED implantation across a multi-hospital system (2019-2023; median follow-up 3.5 years), categorized as implantable cardioverter defibrillator (ICD) (n = 2757) or permanent pacemaker (PPM) (n = 4049). Causal mediation analysis decomposed the effect of device type on major adverse cardiovascular events (MACE) and device extraction into direct and follow-up mediated components, adjusting for demographics and comorbidities. RESULTS: ICD recipients had significantly lower consensus-recommended follow-up rates than PPM recipients (65.3% vs. 79.2%; adjusted OR 0.46, 95% CI 0.40-0.52, p < 0.001) and substantially higher MACE risk (HR 1.89, 95% CI 1.66-2.25, p < 0.001), of which 53.5% was mediated by follow-up adherence. Device extraction rates were lower in ICD recipients (HR 0.30, 95% CI 0.24-0.38), with only 7.9% mediated by follow-up adherence. CONCLUSIONS: More than half of the excess cardiovascular risk in ICD recipients was statistically mediated by suboptimal follow-up adherence-a potentially modifiable pathway. These findings identify follow-up adherence as a potentially important pathway and support further prospective investigation of strategies to improve monitoring and clinical outcomes in high-risk CIED populations.

Journal of Cardiovascular Electrophysiology
Emory University (US)
Openalex Percentile: Top 11%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Consensus‐Recommended Follow‐Up Mediates Cardiovascular Outcomes Disparities Between Implantable Cardioverter Defibrillator and Pacemaker Recipients — Michael Shane Lloyd, Chang Liu, et al. · Journal of Cardiovascular Electrophysiology (2026) | TGRS Research Map | TGRS