Accessible range of motion characterisation of the OpenFlexure microscope

Abstract For any hardware to remain accessible, calibration techniques which rely on low‐cost and obtainable materials such as easily manufactured test slides are necessary. We present a method of measuring the range of motion of the OpenFlexure Microscope using minimal equipment and a computationally light algorithm suitable for running on embedded software in the microscope. The algorithm uses correlation to measure the displacement between consecutive images. The designed range of motion of the OpenFlexure Microscope is . The method described measured the range of motion as . This allows end‐users to identify damage to the microscope and scan samples with confidence.

Authors

Institutions

Publication Details

Journal
Journal of Microscopy
Published
2026-10-30
DOI
https://doi.org/10.1111/jmi.70192
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accessible range of motion characterisation of the OpenFlexure microscope

Richard W Bowman, W. J. Wadsworth, Julian Stirling, Joe Knapper et al.
1 links
Journal of Microscopy
Optical measurement and interference techniques
article

Accessible range of motion characterisation of the OpenFlexure microscope

Richard W Bowman, W. J. Wadsworth, Julian Stirling, Joe Knapper, Ben Chisholm
article en

Abstract

Abstract For any hardware to remain accessible, calibration techniques which rely on low‐cost and obtainable materials such as easily manufactured test slides are necessary. We present a method of measuring the range of motion of the OpenFlexure Microscope using minimal equipment and a computationally light algorithm suitable for running on embedded software in the microscope. The algorithm uses correlation to measure the displacement between consecutive images. The designed range of motion of the OpenFlexure Microscope is . The method described measured the range of motion as . This allows end‐users to identify damage to the microscope and scan samples with confidence.

Journal of Microscopy
University of Bath (GB), University of Glasgow (GB)
Royal Society, University of Glasgow
Openalex Percentile: Top 25%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon