Evaluation of the accuracy of conventional and digital impression techniques for angulated implants: an in vitro study

The aim of this in vitro study was to evaluate the accuracy of implant impressions obtained using open-tray, closed-tray and digital impression techniques for implants placed at different angulations and inter-implant distances in partially edentulous maxillary models. Two acrylic resin maxillary models simulating partial edentulism were fabricated. Each model contained four implants positioned with different angulations (0°, 17°, and 30°) and inter-implant distances (15.3 mm and 25.3 mm). Impressions were obtained using open-tray, closed-tray, and digital impression techniques ( n = 10 per group). Three-dimensional linear deviations of implant positions were measured using a photogrammetry-based system (PiC Dental System). Data were analyzed using multivariate analysis of variance (ANOVA), Shapiro–Wilk, and Mann–Whitney U tests (α = 0.05). Impression accuracy was significantly influenced by impression technique ( p < 0.001 ) and implant angulation ( p < 0.001 ), whereas inter-implant distance had no significant effect ( p = 0.18 ). No statistically significant difference was found between the open-tray and closed-tray techniques overall. For implants with 30° angulation, the open-tray technique demonstrated lower deviation values than both the closed-tray and digital techniques. The highest deviations were observed in digitally produced models associated with angulated implants. İmplant angulation should be considered when selecting an impression protocol for partially edentulous maxillary implant restorations, whereas inter-implant distance did not significantly affect impression accuracy under the conditions evaluated in this study.

Authors

Publication Details

Journal
BMC Oral Health
Published
2026-10-06
DOI
https://doi.org/10.1186/s12903-026-09862-7
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the accuracy of conventional and digital impression techniques for angulated implants: an in vitro study

Nihal Özcan, Sıla Sucuka, Volkan Şahin, Şerife Özge Şahi̇n
BMC Oral Health
Dental Implant Techniques and Outcomes
article

Evaluation of the accuracy of conventional and digital impression techniques for angulated implants: an in vitro study

Nihal Özcan, Sıla Sucuka, Volkan Şahin, Şerife Özge Şahi̇n
article en

Abstract

The aim of this in vitro study was to evaluate the accuracy of implant impressions obtained using open-tray, closed-tray and digital impression techniques for implants placed at different angulations and inter-implant distances in partially edentulous maxillary models. Two acrylic resin maxillary models simulating partial edentulism were fabricated. Each model contained four implants positioned with different angulations (0°, 17°, and 30°) and inter-implant distances (15.3 mm and 25.3 mm). Impressions were obtained using open-tray, closed-tray, and digital impression techniques ( n = 10 per group). Three-dimensional linear deviations of implant positions were measured using a photogrammetry-based system (PiC Dental System). Data were analyzed using multivariate analysis of variance (ANOVA), Shapiro–Wilk, and Mann–Whitney U tests (α = 0.05). Impression accuracy was significantly influenced by impression technique ( p < 0.001 ) and implant angulation ( p < 0.001 ), whereas inter-implant distance had no significant effect ( p = 0.18 ). No statistically significant difference was found between the open-tray and closed-tray techniques overall. For implants with 30° angulation, the open-tray technique demonstrated lower deviation values than both the closed-tray and digital techniques. The highest deviations were observed in digitally produced models associated with angulated implants. İmplant angulation should be considered when selecting an impression protocol for partially edentulous maxillary implant restorations, whereas inter-implant distance did not significantly affect impression accuracy under the conditions evaluated in this study.

BMC Oral Health
Openalex Percentile: Top 9%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of the accuracy of conventional and digital impression techniques for angulated implants: an in vitro study — Nihal Özcan, Sıla Sucuka, et al. · BMC Oral Health (2026) | TGRS Research Map | TGRS