Standardizing wrist x-rays: The human-centered design and evaluation of a wrist x-ray positioning tool

Introduction/Background Small amounts of malrotation can significantly decrease the diagnostic utility of a wrist radiograph. Poorly positioned wrist radiographs can result in repeat scans, additional imaging, and missed injuries. Tolerance for mistakes must be low. Radiographers, especially those with limited training, experience, or resources, may struggle to meet an acceptable standard, underscoring the need for an assistive positioning device that makes proper positioning more accessible. Methods A human-centered design (HCD) process was used during the design of the Tru-Vu, a low-cost novel positioning aid, to assist radiographers with properly positioning of the wrist for x-rays. Initially, observations and preliminary interviews were conducted to understand the challenges faced by various end-users. The identified themes were used to guide the iterative design of the tool and training modules. To evaluate feasibility, the tool and training modules underwent testing using a cadaveric specimen. Results Factors that affect x-ray positioning and shape device adoption were determined from the preliminary end-user interviews. Through post-intervention questionnaires, the Tru-Vu tool and training modules were found to be easy to use/understand and perceived as effective by radiographers. There was no significant difference observed in overall radiograph quality and visualization of the scapholunate (SL) interval during cadaveric feasibility testing. Discussion This study provides insight into the HCD process used to create a novel radiographic positioning aid. The Tru-Vu tool was positively perceived by end-users; however, it did not demonstrate a significant effect on radiograph quality in cadaveric feasibility testing. Further research with live patients is required to demonstrate the clinical effectiveness of the Tru-Vu.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-10-05
DOI
https://doi.org/10.1371/journal.pone.0359437
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Standardizing wrist x-rays: The human-centered design and evaluation of a wrist x-ray positioning tool

Maxwell C. Campbell, Emily Lalone, Jamie Kueneman, Joy Christine MacDermid et al.
PLoS ONE
Orthopedic Surgery and Rehabilitation
article

Standardizing wrist x-rays: The human-centered design and evaluation of a wrist x-ray positioning tool

Maxwell C. Campbell, Emily Lalone, Jamie Kueneman, Joy Christine MacDermid, Gregory J. Garvin, Glenn Schurmans, Laura Vancer, John Henry
article en

Abstract

Introduction/Background Small amounts of malrotation can significantly decrease the diagnostic utility of a wrist radiograph. Poorly positioned wrist radiographs can result in repeat scans, additional imaging, and missed injuries. Tolerance for mistakes must be low. Radiographers, especially those with limited training, experience, or resources, may struggle to meet an acceptable standard, underscoring the need for an assistive positioning device that makes proper positioning more accessible. Methods A human-centered design (HCD) process was used during the design of the Tru-Vu, a low-cost novel positioning aid, to assist radiographers with properly positioning of the wrist for x-rays. Initially, observations and preliminary interviews were conducted to understand the challenges faced by various end-users. The identified themes were used to guide the iterative design of the tool and training modules. To evaluate feasibility, the tool and training modules underwent testing using a cadaveric specimen. Results Factors that affect x-ray positioning and shape device adoption were determined from the preliminary end-user interviews. Through post-intervention questionnaires, the Tru-Vu tool and training modules were found to be easy to use/understand and perceived as effective by radiographers. There was no significant difference observed in overall radiograph quality and visualization of the scapholunate (SL) interval during cadaveric feasibility testing. Discussion This study provides insight into the HCD process used to create a novel radiographic positioning aid. The Tru-Vu tool was positively perceived by end-users; however, it did not demonstrate a significant effect on radiograph quality in cadaveric feasibility testing. Further research with live patients is required to demonstrate the clinical effectiveness of the Tru-Vu.

PLoS ONEVol. 21(10)
Western University (CA), Fanshawe College (CA), Hand and Upper Limb Clinic (CA), St Joseph's Health Care (CA)
Openalex Percentile: Top 9%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.