Piezo 1 and Shear-induced Erythrocyte Transformation and Procoagulant Activity: Implication for LVAD-Induced Bleeding

Mucosal bleeding is a common complication in patients on left ventricular assist device (LVAD) support and often originates at sites of angiodysplasia. LVAD-induced bleeding has been attributed to the loss of large von Willebrand factor (VWF) multimers due to excessive proteolysis; however, this tentative mechanism is not fully supported by clinical and research observations. We have previously shown that phosphatidylserine (PS)-expressing extracellular membrane vesicles (EMVs) are associated with adverse events in LVAD patients. In this study, we used an unbiased proteomic approach to identify EMV-derived molecules associated with LVAD-induced hemostatic complications and studied their role in systemic coagulation dysregulation in vitro and in mouse model. Levels of hemopexin on red blood cell (RBC)-derived EMVs in samples collected 3 months post-LVAD differentiated between patients with bleeding, thrombosis, or uncomplicated assessed 6 months post-LVAD. Furthermore, we detected a subset of deformed RBCs in these patients that were smaller, denser, and less granular than normal RBCs and were prone to hemolysis. The proportion of deformed RBCs increased from 15.3% at baseline to 46.8% after LVAD implantation. These deformed RBCs extensively expressed PS, making them highly procoagulant in vitro and in mice. We found that the mechanosensitive ion channel Piezo1 mediated this RBC deformation and microvesiculation under high shear stress. We further demonstrated that hemolysis and RBC-mediated procoagulant activity contribute to the systemic consumptive coagulopathy that develops after LVAD implantation.

Authors

Institutions

Publication Details

Journal
Blood
Published
2026-10-05
DOI
https://doi.org/10.1182/blood.2026034903
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Piezo 1 and Shear-induced Erythrocyte Transformation and Procoagulant Activity: Implication for LVAD-Induced Bleeding

Priyanka Prathipati, Hongxia Fu, Sinan Tosun, Moritz Stolla et al.
Blood
Mechanical Circulatory Support Devices
article

Piezo 1 and Shear-induced Erythrocyte Transformation and Procoagulant Activity: Implication for LVAD-Induced Bleeding

Priyanka Prathipati, Hongxia Fu, Sinan Tosun, Moritz Stolla, Katie Houck, Jing‐fei Dong, Angelo Nascimbene, Reheman Adili, Manal Alshamrani, Yi Wang, Jianning Zhang, Abdulrahman Alkhalifa, Sam Joy Neuffer, Mengchen Yang, Xiaoyun Fu
article en

Abstract

Mucosal bleeding is a common complication in patients on left ventricular assist device (LVAD) support and often originates at sites of angiodysplasia. LVAD-induced bleeding has been attributed to the loss of large von Willebrand factor (VWF) multimers due to excessive proteolysis; however, this tentative mechanism is not fully supported by clinical and research observations. We have previously shown that phosphatidylserine (PS)-expressing extracellular membrane vesicles (EMVs) are associated with adverse events in LVAD patients. In this study, we used an unbiased proteomic approach to identify EMV-derived molecules associated with LVAD-induced hemostatic complications and studied their role in systemic coagulation dysregulation in vitro and in mouse model. Levels of hemopexin on red blood cell (RBC)-derived EMVs in samples collected 3 months post-LVAD differentiated between patients with bleeding, thrombosis, or uncomplicated assessed 6 months post-LVAD. Furthermore, we detected a subset of deformed RBCs in these patients that were smaller, denser, and less granular than normal RBCs and were prone to hemolysis. The proportion of deformed RBCs increased from 15.3% at baseline to 46.8% after LVAD implantation. These deformed RBCs extensively expressed PS, making them highly procoagulant in vitro and in mice. We found that the mechanosensitive ion channel Piezo1 mediated this RBC deformation and microvesiculation under high shear stress. We further demonstrated that hemolysis and RBC-mediated procoagulant activity contribute to the systemic consumptive coagulopathy that develops after LVAD implantation.

Blood
University of Washington (US), Bloodworks Northwest (US), Tianjin Medical University General Hospital (CN), University of Houston (US), King Abdullah University of Science and Technology (SA), The University of Texas Health Science Center at Houston (US)
Openalex Percentile: Top 23%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines