HierTAC-Net: a robust and explainable hierarchical attention network for multi-configuration gastrointestinal endoscopic image classification

Abstract Colorectal cancer is a leading cause of cancer death worldwide, even though colonoscopy is an effective screening tool. Automated analysis of endoscopic images can help doctors find more lesions and make faster decisions, but current systems usually handle just one task, are tested on clear images from a single dataset, and are rarely compared against working clinicians. We propose HierTAC-Net, a six-stage convolutional classifier that combines inverted residual blocks, triple attention at three resolution levels, and ConvNeXt-style refinement. We train the model once on the eight-class Kvasir-v2 dataset, and from a single softmax output, it generates seven clinical readouts without retraining, including full diagnosis, anatomical landmark checks, pathological classification, and polyp screening. In stratified five-fold cross-validation, HierTAC-Net achieves 94.24% accuracy with a 110.14 MB footprint and 0.32 ms GPU latency, outperforming the strongest compact attention baseline while remaining far lighter than large fine-tuned models. Our ablation study isolates the contribution of attention placement from the operator itself and shows that early insertion with triple attention provides the largest consistent gain. We further evaluate the model under compounded blur, uneven illumination, and specular highlights at three severity levels, and on an aligned eight-class subset of HyperKvasir without fine-tuning, where it retains 95.98% accuracy and 96.00% F1-score. In a supervised reading session, HierTAC-Net outperforms five gastroenterologists with 1 to 8 years of experience on a shared 200-image subset. These results indicate that the proposed architecture is suitable for real-time deployment and remains stable under common artifacts and across two clinical collections.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-10-05
DOI
https://doi.org/10.1038/s41598-026-70788-9
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HierTAC-Net: a robust and explainable hierarchical attention network for multi-configuration gastrointestinal endoscopic image classification

Amith Abdullah Khandakar, Tamjeed Alam, Rizoan Toufiq, Mohamed Arselene Ayari et al.
Scientific Reports
Colorectal Cancer Screening and Detection
article

HierTAC-Net: a robust and explainable hierarchical attention network for multi-configuration gastrointestinal endoscopic image classification

Amith Abdullah Khandakar, Tamjeed Alam, Rizoan Toufiq, Mohamed Arselene Ayari, Sawal Hamid Md Ali, Md. Masum Mia
article en

Abstract

Abstract Colorectal cancer is a leading cause of cancer death worldwide, even though colonoscopy is an effective screening tool. Automated analysis of endoscopic images can help doctors find more lesions and make faster decisions, but current systems usually handle just one task, are tested on clear images from a single dataset, and are rarely compared against working clinicians. We propose HierTAC-Net, a six-stage convolutional classifier that combines inverted residual blocks, triple attention at three resolution levels, and ConvNeXt-style refinement. We train the model once on the eight-class Kvasir-v2 dataset, and from a single softmax output, it generates seven clinical readouts without retraining, including full diagnosis, anatomical landmark checks, pathological classification, and polyp screening. In stratified five-fold cross-validation, HierTAC-Net achieves 94.24% accuracy with a 110.14 MB footprint and 0.32 ms GPU latency, outperforming the strongest compact attention baseline while remaining far lighter than large fine-tuned models. Our ablation study isolates the contribution of attention placement from the operator itself and shows that early insertion with triple attention provides the largest consistent gain. We further evaluate the model under compounded blur, uneven illumination, and specular highlights at three severity levels, and on an aligned eight-class subset of HyperKvasir without fine-tuning, where it retains 95.98% accuracy and 96.00% F1-score. In a supervised reading session, HierTAC-Net outperforms five gastroenterologists with 1 to 8 years of experience on a shared 200-image subset. These results indicate that the proposed architecture is suitable for real-time deployment and remains stable under common artifacts and across two clinical collections.

Scientific ReportsVol. 16(1)
Rajshahi University of Engineering and Technology (BD), Qatar University (QA), National University of Malaysia (MY)
Openalex Percentile: Top 16%
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.