Numerical study on capacitive metal rod position detector in double-layer medium

Position signals of control rods are important parameters that should be measured during the operation of nuclear reactors. The performance of capacitive detectors for measuring control rod positions in a double-layer medium is numerically studied in this paper. According to the experimental results of concave electrodes capacitive detectors, the numerical model is verified. The mathematical expression of the detector signal is derived as a function of rod position and liquid level. The error characteristics of the capacitive detectors for measuring the eccentric metal rod are revealed. The method for evaluating measuring errors of capacitive detectors in double-layer medium is constructed. The relation between flare angles of electrodes and measuring errors is studied, and the optimization method of the flare angles is discussed. The design of the integrated capacitive metal rod position detector (CMRPD) is proposed. Measuring errors and performance of the detector are evaluated.

Authors

Institutions

Publication Details

Journal
Annals of Nuclear Energy
Published
2026-10-03
DOI
https://doi.org/10.1016/j.anucene.2026.112889
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical study on capacitive metal rod position detector in double-layer medium

Hanliang Bo, Benke Qin, Wei Xiong, Zijia Chen et al.
Annals of Nuclear Energy
Electrical and Bioimpedance Tomography
article

Numerical study on capacitive metal rod position detector in double-layer medium

Hanliang Bo, Benke Qin, Wei Xiong, Zijia Chen, Yanlin Li
article en

Abstract

Position signals of control rods are important parameters that should be measured during the operation of nuclear reactors. The performance of capacitive detectors for measuring control rod positions in a double-layer medium is numerically studied in this paper. According to the experimental results of concave electrodes capacitive detectors, the numerical model is verified. The mathematical expression of the detector signal is derived as a function of rod position and liquid level. The error characteristics of the capacitive detectors for measuring the eccentric metal rod are revealed. The method for evaluating measuring errors of capacitive detectors in double-layer medium is constructed. The relation between flare angles of electrodes and measuring errors is studied, and the optimization method of the flare angles is discussed. The design of the integrated capacitive metal rod position detector (CMRPD) is proposed. Measuring errors and performance of the detector are evaluated.

Annals of Nuclear EnergyVol. 242
Tsinghua University (CN)
Openalex Percentile: Top 22%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical study on capacitive metal rod position detector in double-layer medium — Hanliang Bo, Benke Qin, et al. · Annals of Nuclear Energy (2026) | TGRS Research Map | TGRS