An Online Adaptive Intelligent Dosing Framework for Drift-Aware Industrial Fluoride Removal

Calcium-salt precipitation is a widely used compliance-control process for industrial fluoride-containing wastewater. Its core objective is to maintain stable effluent fluoride compliance while avoiding unnecessary chemical consumption. In real industrial defluorination systems, however, effluent fluoride is not an instantaneous response to the current influent quality and dosing action. The process therefore exhibits hydraulic delay, nonlinear response, uneven sampling, and process drift, which make a single fixed offline model unreliable for long-term prediction and dosing decisions. Hence, this paper proposes an online adaptive intelligent dosing framework for industrial fluoride removal. First, influent-side variables, dosing actions, and effluent fluoride measurements are aligned according to hydraulic retention time, and lagged variables, rolling statistics, exponentially weighted memory, and first-order differences are constructed as time-enhanced tabular features. Second, a monotonic XGBoost model is adopted as the backbone predictor. The prior that increasing calcium dosage should not increase predicted effluent fluoride is embedded as a monotonic constraint, yielding a more physically consistent dosage-response model. Third, online dosing is formulated as a penalty-based dosage optimization problem to generate a base recommended dosage, and an adaptive safety dose band constrains the executable dosage to reduce underdosing and overdosing risks. Experiments show that time-enhanced features improve short-term prediction under similar operating conditions, the monotonic backbone provides reasonable dosage-response trends, and historical replay together with drift simulations verifies the effectiveness of local adaptation and safety constraints. The proposed method provides a practical solution for intelligent calcium dosing in industrial fluoride wastewater treatment by balancing prediction rationality, online adaptability, and deployability.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-10-01
DOI
https://doi.org/10.3390/electronics15194504
Primary Topic
Fluoride Effects and Removal
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

An Online Adaptive Intelligent Dosing Framework for Drift-Aware Industrial Fluoride Removal

Shuwei Zhu, Wei Fang, Ye Tian, Laizhen Hua
Electronics
Fluoride Effects and Removal
article

An Online Adaptive Intelligent Dosing Framework for Drift-Aware Industrial Fluoride Removal

Shuwei Zhu, Wei Fang, Ye Tian, Laizhen Hua
article en

Abstract

Calcium-salt precipitation is a widely used compliance-control process for industrial fluoride-containing wastewater. Its core objective is to maintain stable effluent fluoride compliance while avoiding unnecessary chemical consumption. In real industrial defluorination systems, however, effluent fluoride is not an instantaneous response to the current influent quality and dosing action. The process therefore exhibits hydraulic delay, nonlinear response, uneven sampling, and process drift, which make a single fixed offline model unreliable for long-term prediction and dosing decisions. Hence, this paper proposes an online adaptive intelligent dosing framework for industrial fluoride removal. First, influent-side variables, dosing actions, and effluent fluoride measurements are aligned according to hydraulic retention time, and lagged variables, rolling statistics, exponentially weighted memory, and first-order differences are constructed as time-enhanced tabular features. Second, a monotonic XGBoost model is adopted as the backbone predictor. The prior that increasing calcium dosage should not increase predicted effluent fluoride is embedded as a monotonic constraint, yielding a more physically consistent dosage-response model. Third, online dosing is formulated as a penalty-based dosage optimization problem to generate a base recommended dosage, and an adaptive safety dose band constrains the executable dosage to reduce underdosing and overdosing risks. Experiments show that time-enhanced features improve short-term prediction under similar operating conditions, the monotonic backbone provides reasonable dosage-response trends, and historical replay together with drift simulations verifies the effectiveness of local adaptation and safety constraints. The proposed method provides a practical solution for intelligent calcium dosing in industrial fluoride wastewater treatment by balancing prediction rationality, online adaptability, and deployability.

ElectronicsVol. 15(19)
Jiangnan University (CN), China Electronics Corporation (China) (CN)
Clean water and sanitation
Openalex Percentile: Top 23%
Fluoride Effects and Removal
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.