ARP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS DETERMINATION OF NIRMATRELVIR AND RITONAVIR IN TABLET FORMULATION

For the quantitative measurement of Ritonavir and Nirmatrelvir in pharmaceutical dosage form, an easy quick, accurate, sensitive, and repeatable reverse phase high performance liquid chromatography approach has been devised. Ritonavir and Nirmatrelvir were separated chromatographically using a Waters Alliance-e2695 using a Luna Phenyl Hexyl column and a mobile phase that contained 40:60% v/v acetonitrile:ammonium acetate pH-3.0/OPA. A photodiode array detector operating at room temperature was used to measure the 1.0 ml/min flow rate by absorption at 266 nm. For Ritonavir and Nirmatrelvir, the number of theoretical plates and tailing factors were NLT 2000 and should not exceed 2, respectively. Every measurement's relative standard deviation of peak areas is consistently smaller than 2.0. ICH principles were followed in the validation of the suggested approach. For the quantitative analysis of Ritonavir and the stability research of Nirmatrelvir, the approach was determined to be straightforward, affordable, appropriate, exact, accurate, and reliable.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-01
DOI
https://doi.org/10.5281/zenodo.23075680
Primary Topic
HIV/AIDS drug development and treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

ARP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS DETERMINATION OF NIRMATRELVIR AND RITONAVIR IN TABLET FORMULATION

Shaik Nabi Rasool, G. Bhargav, P. V. Balaji, K. Mangamma
Zenodo (CERN European Organization for Nuclear Research)
HIV/AIDS drug development and treatment
article

ARP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS DETERMINATION OF NIRMATRELVIR AND RITONAVIR IN TABLET FORMULATION

Shaik Nabi Rasool, G. Bhargav, P. V. Balaji, K. Mangamma
article en

Abstract

For the quantitative measurement of Ritonavir and Nirmatrelvir in pharmaceutical dosage form, an easy quick, accurate, sensitive, and repeatable reverse phase high performance liquid chromatography approach has been devised. Ritonavir and Nirmatrelvir were separated chromatographically using a Waters Alliance-e2695 using a Luna Phenyl Hexyl column and a mobile phase that contained 40:60% v/v acetonitrile:ammonium acetate pH-3.0/OPA. A photodiode array detector operating at room temperature was used to measure the 1.0 ml/min flow rate by absorption at 266 nm. For Ritonavir and Nirmatrelvir, the number of theoretical plates and tailing factors were NLT 2000 and should not exceed 2, respectively. Every measurement's relative standard deviation of peak areas is consistently smaller than 2.0. ICH principles were followed in the validation of the suggested approach. For the quantitative analysis of Ritonavir and the stability research of Nirmatrelvir, the approach was determined to be straightforward, affordable, appropriate, exact, accurate, and reliable.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 12%
HIV/AIDS drug development and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ARP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS DETERMINATION OF NIRMATRELVIR AND RITONAVIR IN TABLET FORMULATION — Shaik Nabi Rasool, G. Bhargav, et al. · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS