Rapid isocratic HPLC determination of fipronil, (S)-methoprene, and major related substances using an end-capped monolithic column

In this study, a simple and rapid isocratic reversed-phase high-performance liquid chromatography (HPLC) method was developed. This method allows the simultaneous determination of active substances and their major impurities, fipronil sulfone and cis-methoprene, in spot-on products containing fipronil and (S)-methoprene. Separation was achieved using an end-capped monolithic column, with an isocratic mobile phase composed of acetonitrile and 0.1% formic acid (70:30, v/v) at 1.0 mL/min and UV detection at 245 nm. Compared to conventional particulate columns, this method provides significant advantages, including very low system back-pressure (~13 bar) and a short analysis time (~12 min).The method was validated for selectivity, linearity, precision, accuracy, limit of detection (LOD), limit of quantification (LOQ), and system suitability. Good linearity was obtained (R² ≥ 0.995), and repeatability (%RSD < 2.0) and recovery values ranged from 95.68% to 99.07%. The method enabled detection of impurities below 0.05%.The environmental impact of the method was evaluated using AGREE (Analytical GREEnness Metric) and GAPI (Green Analytical Procedure Index). The reduced analysis time and low solvent consumption confirmed the method’s compliance with green analytical chemistry (GAC) principles. Following validation, the method was applied to ten commercial products available on the Türkiye market. The active substance content of all samples was within the ±10% specification limits, and the levels of major impurities were found to be below acceptable thresholds.This study proposes a practical, cost-effective, and environmentally friendly HPLC method based on an end-capped monolithic column for routine quality control and impurity profiling.

Authors

Institutions

Publication Details

Journal
Turkish Journal of Analytical Chemistry
Published
2026-09-30
DOI
https://doi.org/10.51435/turkjac.1944091
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Rapid isocratic HPLC determination of fipronil, (S)-methoprene, and major related substances using an end-capped monolithic column

Onur Demir
Turkish Journal of Analytical Chemistry
Analytical chemistry methods development
article

Rapid isocratic HPLC determination of fipronil, (S)-methoprene, and major related substances using an end-capped monolithic column

Onur Demir
article en

Abstract

In this study, a simple and rapid isocratic reversed-phase high-performance liquid chromatography (HPLC) method was developed. This method allows the simultaneous determination of active substances and their major impurities, fipronil sulfone and cis-methoprene, in spot-on products containing fipronil and (S)-methoprene. Separation was achieved using an end-capped monolithic column, with an isocratic mobile phase composed of acetonitrile and 0.1% formic acid (70:30, v/v) at 1.0 mL/min and UV detection at 245 nm. Compared to conventional particulate columns, this method provides significant advantages, including very low system back-pressure (~13 bar) and a short analysis time (~12 min).The method was validated for selectivity, linearity, precision, accuracy, limit of detection (LOD), limit of quantification (LOQ), and system suitability. Good linearity was obtained (R² ≥ 0.995), and repeatability (%RSD < 2.0) and recovery values ranged from 95.68% to 99.07%. The method enabled detection of impurities below 0.05%.The environmental impact of the method was evaluated using AGREE (Analytical GREEnness Metric) and GAPI (Green Analytical Procedure Index). The reduced analysis time and low solvent consumption confirmed the method’s compliance with green analytical chemistry (GAC) principles. Following validation, the method was applied to ten commercial products available on the Türkiye market. The active substance content of all samples was within the ±10% specification limits, and the levels of major impurities were found to be below acceptable thresholds.This study proposes a practical, cost-effective, and environmentally friendly HPLC method based on an end-capped monolithic column for routine quality control and impurity profiling.

Turkish Journal of Analytical ChemistryVol. 8(3)
İstanbul Pendik Veteriner Kontrol Enstitüsü (TR)
Openalex Percentile: Top 17%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rapid isocratic HPLC determination of fipronil, (S)-methoprene, and major related substances using an end-capped monolithic column — Onur Demir · Turkish Journal of Analytical Chemistry (2026) | TGRS Research Map | TGRS