Rapid Fabrication of Round Flexdym Microchannels via Direct PDMS (Thermoset)-to-Flexdym (Thermoplastic) Thermal Replication

Round microchannels provide physiologically relevant flow environments and improved fluidic performance compared with conventional rectangular geometries; however, their scalable fabrication in potentially biocompatible thermoplastic substrates remains challenging. Here, we present a rapid and low-cost PDMS-to-Flexdym thermal replication strategy to directly transform round microchannel architectures from a reusable compliant thermoset PDMS mold into a thermoplastic microfluidic platform. Round PDMS convex molds generated by thermal air expansion followed by PDMS double casting were used for heat-assisted conformal replication to transform spatially varying complex round microchannels into Flexdym. The method successfully transferred complex serpentine, branched, and interconnected channel architectures while preserving continuous flow paths and curved geometries. Temperature-dependent framework and experimentation revealed improved vertical feature recovery with increasing embossing temperature, while lateral dimensions remained highly conserved. Across representative channel widths of ~37–249 µm, replicated Flexdym channels achieved width and height transfer ratios of approximately 99–103% and 93–105%, respectively. Sequential dimensional analysis among concave PDMS, convex PDMS, and Flexdym replicas showed no statistically significant differences in channel width or height (p > 0.05), confirming high geometric fidelity throughout the replication process. AFM, SEM, and stylus profilometry results further verified the preservation of surface characteristics, rounded cross-sectional morphology, and reproducible channel profiles, with Flexdym surface roughness reduced from ~84.1 nm (PDMS mold) to ~25.1 nm in Flexdym after replication. Finally, integration of the replicated round channels into a multilayer microvalve demonstrated functional fluidic control through syringe-assisted compressed air actuation, supported by two-phase moving-mesh simulation and analytical air compression modeling. This strategy provides a practical route for translating PDMS-based round microchannel prototyping into scalable, more biocompatible thermoplastic microfluidic platforms for building next-generation microphysiological systems and bioengineering applications.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-09-30
DOI
https://doi.org/10.3390/polym18192387
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Rapid Fabrication of Round Flexdym Microchannels via Direct PDMS (Thermoset)-to-Flexdym (Thermoplastic) Thermal Replication

Md. Emamul Kabir, Kwang Wook Oh, Sonali Garg, Aldrian Muhaxheri et al.
Polymers
Microfluidic and Capillary Electrophoresis Applications
article

Rapid Fabrication of Round Flexdym Microchannels via Direct PDMS (Thermoset)-to-Flexdym (Thermoplastic) Thermal Replication

Md. Emamul Kabir, Kwang Wook Oh, Sonali Garg, Aldrian Muhaxheri, Paras N. Prasad
article en

Abstract

Round microchannels provide physiologically relevant flow environments and improved fluidic performance compared with conventional rectangular geometries; however, their scalable fabrication in potentially biocompatible thermoplastic substrates remains challenging. Here, we present a rapid and low-cost PDMS-to-Flexdym thermal replication strategy to directly transform round microchannel architectures from a reusable compliant thermoset PDMS mold into a thermoplastic microfluidic platform. Round PDMS convex molds generated by thermal air expansion followed by PDMS double casting were used for heat-assisted conformal replication to transform spatially varying complex round microchannels into Flexdym. The method successfully transferred complex serpentine, branched, and interconnected channel architectures while preserving continuous flow paths and curved geometries. Temperature-dependent framework and experimentation revealed improved vertical feature recovery with increasing embossing temperature, while lateral dimensions remained highly conserved. Across representative channel widths of ~37–249 µm, replicated Flexdym channels achieved width and height transfer ratios of approximately 99–103% and 93–105%, respectively. Sequential dimensional analysis among concave PDMS, convex PDMS, and Flexdym replicas showed no statistically significant differences in channel width or height (p > 0.05), confirming high geometric fidelity throughout the replication process. AFM, SEM, and stylus profilometry results further verified the preservation of surface characteristics, rounded cross-sectional morphology, and reproducible channel profiles, with Flexdym surface roughness reduced from ~84.1 nm (PDMS mold) to ~25.1 nm in Flexdym after replication. Finally, integration of the replicated round channels into a multilayer microvalve demonstrated functional fluidic control through syringe-assisted compressed air actuation, supported by two-phase moving-mesh simulation and analytical air compression modeling. This strategy provides a practical route for translating PDMS-based round microchannel prototyping into scalable, more biocompatible thermoplastic microfluidic platforms for building next-generation microphysiological systems and bioengineering applications.

PolymersVol. 18(19)
University at Buffalo, State University of New York (US)
Openalex Percentile: Top 22%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.