Diagnostic Radiographers' Application of the Radiation Protection Principles of Justification, Optimisation and Dose Limits in Mpumalanga Province, South Africa

INTRODUCTION: The effective application of radiation protection principles is essential for minimising unnecessary radiation exposure and reducing associated risks to patients, personnel, and the public. This study investigated the application of radiation protection principles by diagnostic radiographers in Mpumalanga province, South Africa. METHODS: The quantitative cross-sectional study employed stratified random sampling and an online questionnaire to collect data from diagnostic radiographers working in Mpumalanga hospitals. The data were analysed using descriptive and inferential statistics. RESULTS: The survey achieved a response rate of 85.6% (n = 125, N = 146). Most participants (38.4%, n = 48) had 0-5 years of work experience. Referral forms often lacked sufficient clinical history (64.8%, n = 81), with diagnostic radiographers frequently supplementing by assessing the body region of concern (49.2%, n = 60). Lack of communication between radiologists and diagnostic radiographers was noted when referrals were incomplete (31.3%, n = 36) or when requested examinations did not correspond with the clinical history (32.8%, n = 38). Most participants (66.4%, n = 81) felt undervalued due to hierarchical structures. Most X-ray rooms had functional warning lights (80%, n = 84). Full lead shields (98.1%, n = 102) were widely accessible, and lead goggles (33.7%, n = 34) were the least accessible. Although most participants were issued with personal radiation monitoring devices (97.1%, n = 99), only 53.5% (n = 53) reported consistent use, and 33.3% (n = 32) received radiation dose readings. CONCLUSION: The application of radiation protection principles was inconsistent. Justification was achieved through referral assessment but was compromised by systemic barriers. Optimisation demonstrated suitable room designs but was limited by resource accessibility. Dose limitation was hindered by device usage and feedback despite high issuance.

Authors

Institutions

Publication Details

Journal
Journal of Medical Radiation Sciences
Published
2026-09-30
DOI
https://doi.org/10.1002/jmrs.70122
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Diagnostic Radiographers' Application of the Radiation Protection Principles of Justification, Optimisation and Dose Limits in Mpumalanga Province, South Africa

N. Moolman, Shantel Lewis, Wandile Witness Mkhonza
Journal of Medical Radiation Sciences
Radiation Dose and Imaging
article

Diagnostic Radiographers' Application of the Radiation Protection Principles of Justification, Optimisation and Dose Limits in Mpumalanga Province, South Africa

N. Moolman, Shantel Lewis, Wandile Witness Mkhonza
article en

Abstract

INTRODUCTION: The effective application of radiation protection principles is essential for minimising unnecessary radiation exposure and reducing associated risks to patients, personnel, and the public. This study investigated the application of radiation protection principles by diagnostic radiographers in Mpumalanga province, South Africa. METHODS: The quantitative cross-sectional study employed stratified random sampling and an online questionnaire to collect data from diagnostic radiographers working in Mpumalanga hospitals. The data were analysed using descriptive and inferential statistics. RESULTS: The survey achieved a response rate of 85.6% (n = 125, N = 146). Most participants (38.4%, n = 48) had 0-5 years of work experience. Referral forms often lacked sufficient clinical history (64.8%, n = 81), with diagnostic radiographers frequently supplementing by assessing the body region of concern (49.2%, n = 60). Lack of communication between radiologists and diagnostic radiographers was noted when referrals were incomplete (31.3%, n = 36) or when requested examinations did not correspond with the clinical history (32.8%, n = 38). Most participants (66.4%, n = 81) felt undervalued due to hierarchical structures. Most X-ray rooms had functional warning lights (80%, n = 84). Full lead shields (98.1%, n = 102) were widely accessible, and lead goggles (33.7%, n = 34) were the least accessible. Although most participants were issued with personal radiation monitoring devices (97.1%, n = 99), only 53.5% (n = 53) reported consistent use, and 33.3% (n = 32) received radiation dose readings. CONCLUSION: The application of radiation protection principles was inconsistent. Justification was achieved through referral assessment but was compromised by systemic barriers. Optimisation demonstrated suitable room designs but was limited by resource accessibility. Dose limitation was hindered by device usage and feedback despite high issuance.

Journal of Medical Radiation Sciences
University of Johannesburg (ZA)
Openalex Percentile: Top 12%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.