Artificial Intelligence-Supported Automated Microscopy for Malaria Diagnosis: A Multicenter Study.

BACKGROUND: Accurate malaria diagnosis is key for patient management, surveillance, and control. Automated microscopy can overcome the variation observed among microscopists and is a promising new tool for diagnosis. The Noul miLab integrates smear preparation, staining, imaging, and artificial intelligence-supported parasite detection in a portable device. METHODS: A total of 2201 samples were collected from febrile patients across 2 sites in Ethiopia, where Plasmodium falciparum and Plasmodium vivax are frequent, and in Ghana, where P. falciparum transmission is intense. Samples were screened using local microscopy at the health center, miLab, and rapid diagnostic tests. Quantitative polymerase chain reaction (qPCR) and expert microscopy were used as gold standards. RESULTS: The miLab reached a sensitivity for P. falciparum diagnosis of 96.3% (335 of 348) using expert microscopy as the gold standard and a sensitivity of 97.4% (298 of 306) using qPCR-positive infections at densities >200 parasites/µL as the gold standard. The sensitivity of miLab for P. vivax was 96.8% (399 of 412) using expert microscopy as the gold standard and 95.9% (419 of 437) using qPCR-positive infections at densities >200 parasites/µL as the gold standard. Compared to qPCR, specificity was 98.8% for P. falciparum and 97.8% for P. vivax. miLab was significantly more sensitive than microscopy conducted at the health center. In Ethiopia, among miLab-positive samples, miLab assigned the correct parasite species to 98.7% of P. falciparum and 96.2% of P. vivax mono-infections. CONCLUSIONS: The miLab automated microscope shows high sensitivity and specificity for P. falciparum and P. vivax diagnosis.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-09-30
DOI
https://doi.org/10.1093/cid/ciag484
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Artificial Intelligence-Supported Automated Microscopy for Malaria Diagnosis: A Multicenter Study.

Dawit Hawaria, Colins O. Oduma, Kingsley Badu, Yalemwork Ewnetu et al.
PubMed
Digital Imaging for Blood Diseases
article

Artificial Intelligence-Supported Automated Microscopy for Malaria Diagnosis: A Multicenter Study.

Dawit Hawaria, Colins O. Oduma, Kingsley Badu, Yalemwork Ewnetu, Cristian Koepfli, Birhanu Lulu, Isaac Asenso Brobbey-Kyei, Tolulope Adeyemi Kayode, Berhane Nega, Henry Kamugisha, Abdul-Hakim Mutala, Wossenseged Lemma
article en

Abstract

BACKGROUND: Accurate malaria diagnosis is key for patient management, surveillance, and control. Automated microscopy can overcome the variation observed among microscopists and is a promising new tool for diagnosis. The Noul miLab integrates smear preparation, staining, imaging, and artificial intelligence-supported parasite detection in a portable device. METHODS: A total of 2201 samples were collected from febrile patients across 2 sites in Ethiopia, where Plasmodium falciparum and Plasmodium vivax are frequent, and in Ghana, where P. falciparum transmission is intense. Samples were screened using local microscopy at the health center, miLab, and rapid diagnostic tests. Quantitative polymerase chain reaction (qPCR) and expert microscopy were used as gold standards. RESULTS: The miLab reached a sensitivity for P. falciparum diagnosis of 96.3% (335 of 348) using expert microscopy as the gold standard and a sensitivity of 97.4% (298 of 306) using qPCR-positive infections at densities >200 parasites/µL as the gold standard. The sensitivity of miLab for P. vivax was 96.8% (399 of 412) using expert microscopy as the gold standard and 95.9% (419 of 437) using qPCR-positive infections at densities >200 parasites/µL as the gold standard. Compared to qPCR, specificity was 98.8% for P. falciparum and 97.8% for P. vivax. miLab was significantly more sensitive than microscopy conducted at the health center. In Ethiopia, among miLab-positive samples, miLab assigned the correct parasite species to 98.7% of P. falciparum and 96.2% of P. vivax mono-infections. CONCLUSIONS: The miLab automated microscope shows high sensitivity and specificity for P. falciparum and P. vivax diagnosis.

PubMed
University of Notre Dame (US), Hawassa University (ET), Tamale Teaching Hospital (GH), Kwame Nkrumah University of Science and Technology (GH), Uzima University College (KE), University of Gondar (ET)
Good health and well-being
Openalex Percentile: Top 14%
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.