Errors in the Laboratory X-ray Absorption Near Edge Structure with Respect to Species Analysis in Slags Considering Leak Radiation

Abstract The knowledge on the element species in slags is of great importance for, e.g., process control or recovery of valuable materials. X-ray absorption near-edge spectroscopy (XANES) is a suitable method, especially for slags, since it allows element speciation not only in crystalline but also in amorphous phases. The sample preparation as well as the evaluation via linear combination fitting of reference spectra are relevant influencing factors for the results. Errors can occur due to, e.g., improperly prepared samples, damping effects, and inappropriate reference materials. In this study, the origin of spectral damping was investigated with two lab-based spectrometers on a sample series of Fe2O3 prepared as pellets with different masses. Additionally, an electric arc furnace (EAF) slag served as a complex model sample to determine the influence of dampened spectra on the speciation analysis through linear combination fitting. Powder X-ray diffraction (PXRD), X-ray fluorescence spectrometry (XRF), electron probe microanalysis (EPMA), and inductively coupled plasma optical emission spectroscopy (ICP-OES) were employed as complementary and supporting characterization methods.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-09-30
DOI
https://doi.org/10.1021/acs.analchem.6c02072
Primary Topic
X-ray Spectroscopy and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Errors in the Laboratory X-ray Absorption Near Edge Structure with Respect to Species Analysis in Slags Considering Leak Radiation

Sven Karsten Hampel, Jessica Hiller, Joanna Kolny‐Olesiak, Ursula E. A. Fittschen et al.
Analytical Chemistry
X-ray Spectroscopy and Fluorescence Analysis
article

Errors in the Laboratory X-ray Absorption Near Edge Structure with Respect to Species Analysis in Slags Considering Leak Radiation

Sven Karsten Hampel, Jessica Hiller, Joanna Kolny‐Olesiak, Ursula E. A. Fittschen, Thomas Schirmer
article en

Abstract

Abstract The knowledge on the element species in slags is of great importance for, e.g., process control or recovery of valuable materials. X-ray absorption near-edge spectroscopy (XANES) is a suitable method, especially for slags, since it allows element speciation not only in crystalline but also in amorphous phases. The sample preparation as well as the evaluation via linear combination fitting of reference spectra are relevant influencing factors for the results. Errors can occur due to, e.g., improperly prepared samples, damping effects, and inappropriate reference materials. In this study, the origin of spectral damping was investigated with two lab-based spectrometers on a sample series of Fe2O3 prepared as pellets with different masses. Additionally, an electric arc furnace (EAF) slag served as a complex model sample to determine the influence of dampened spectra on the speciation analysis through linear combination fitting. Powder X-ray diffraction (PXRD), X-ray fluorescence spectrometry (XRF), electron probe microanalysis (EPMA), and inductively coupled plasma optical emission spectroscopy (ICP-OES) were employed as complementary and supporting characterization methods.

Analytical Chemistry
Clausthal University of Technology (DE)
Life in Land
Openalex Percentile: Top 12%
X-ray Spectroscopy and Fluorescence Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.