A Removable Mechanical Interface for Non-Invasive Strain Measurement in Paddle Shafts: Iterative Design and Experimental Characterization

Accurate force measurement on paddle shafts is essential for performance assessment and technique refinement, yet existing tools typically require permanent shaft modification or recalibration after each utilization. This study presents the iterative design and characterization of a removable, non-invasive interface for strain measurement on cylindrical paddle shafts, designed for repeated installation without bonding. A total of nineteen configurations were developed through an iterative five-phase design process using fused filament fabrication (FFF) and evaluated under static and dynamic laboratory loading, including an exploratory on-water assessment of the distributed-clamping shell with one athlete. Performance was benchmarked against a bonded reference using linearity, hysteresis, repeatability, and signal fidelity. Rigid shells improved linearity but retained high hysteresis, while distributed clamping introduced placement-dependent uncertainty. Beam-based geometries reduced contact sensitivity, and the distal gauge position of an inverted U-shaped beam provided the closest agreement with the reference response under the tested conditions, reaching a coefficient of determination of 0.954–0.990, a mean absolute error of 7.8–17.7 N, and hysteresis of 3.4–9.1% of the applied load range. Its residual hysteresis was concentrated in the low-force unloading region, predominantly near the transition from the propulsive to the recovery phase. No configuration eliminated all trade-offs; acceptable performance depended on the intended measurement context. The resulting framework provides testable design indications for the future development of removable strain-sensing interfaces on cylindrical structures.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-09-30
DOI
https://doi.org/10.3390/s26196220
Primary Topic
Piezoelectric Actuators and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

A Removable Mechanical Interface for Non-Invasive Strain Measurement in Paddle Shafts: Iterative Design and Experimental Characterization

Ana M. Amaro, M. I. Cruz, Beatriz Branquinho Gomes, Luis Manuel Roseiro et al.
Sensors
Piezoelectric Actuators and Control
article

A Removable Mechanical Interface for Non-Invasive Strain Measurement in Paddle Shafts: Iterative Design and Experimental Characterization

Ana M. Amaro, M. I. Cruz, Beatriz Branquinho Gomes, Luis Manuel Roseiro, Marco Silva
article en

Abstract

Accurate force measurement on paddle shafts is essential for performance assessment and technique refinement, yet existing tools typically require permanent shaft modification or recalibration after each utilization. This study presents the iterative design and characterization of a removable, non-invasive interface for strain measurement on cylindrical paddle shafts, designed for repeated installation without bonding. A total of nineteen configurations were developed through an iterative five-phase design process using fused filament fabrication (FFF) and evaluated under static and dynamic laboratory loading, including an exploratory on-water assessment of the distributed-clamping shell with one athlete. Performance was benchmarked against a bonded reference using linearity, hysteresis, repeatability, and signal fidelity. Rigid shells improved linearity but retained high hysteresis, while distributed clamping introduced placement-dependent uncertainty. Beam-based geometries reduced contact sensitivity, and the distal gauge position of an inverted U-shaped beam provided the closest agreement with the reference response under the tested conditions, reaching a coefficient of determination of 0.954–0.990, a mean absolute error of 7.8–17.7 N, and hysteresis of 3.4–9.1% of the applied load range. Its residual hysteresis was concentrated in the low-force unloading region, predominantly near the transition from the propulsive to the recovery phase. No configuration eliminated all trade-offs; acceptable performance depended on the intended measurement context. The resulting framework provides testable design indications for the future development of removable strain-sensing interfaces on cylindrical structures.

SensorsVol. 26(19)
Polytechnic Institute of Coimbra (PT), Research Center for Natural Resources, Environment and Society (PT), University of Coimbra (PT)
Openalex Percentile: Top 16%
Piezoelectric Actuators and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.