Validity and reliability of the APECS mobile application for assessing knee joint position sense during functional squat tasks in healthy adults

BackgroundKnee joint position sense (JPS) is a vital component of proprioception, significantly impacting functional performance and clinical outcomes.ObjectiveThis study aimed to investigate the concurrent validity and the intra- and inter-tester reliability of APECS-derived JPS error measures during three different squat ranges.MethodsSixty-two participants (mean age: 25.5 ± 3.9 years) were evaluated across three sessions. Knee JPS was measured at low (30-50°), moderate (50-70°), and deep (70-90°) squat ranges. Concurrent validity was evaluated by comparing APECS-derived JPS error measures with digital goniometer-derived measures. Intra-tester reliability was assessed by comparing Sessions 2 and 3 (T1), and inter-tester reliability by comparing T1 and T2 in Session 3. JPS error was quantified using absolute (AAE), relative (RAE), and variable (VAE) angular errors.ResultsCorrelations between APECS- and digital goniometer-derived JPS error measures were low and non-significant across all ranges (r = -0.22 to 0.08). Intra-tester reliability was good only for AAE (ICC = 0.85) and RAE (ICC = 0.79) in the deep squat range, with poor reliability elsewhere. Inter-tester reliability was predominantly poor, with moderate reliability only for VAE in the moderate range (ICC = 0.69).ConclusionUnder the present protocol, APECS-derived JPS error measures showed limited agreement with digital goniometer-derived measures and inconsistent reliability across squat ranges and error parameters. These findings are specific to the present APECS-based assessment protocol and reference method and should not be generalized to the overall validity or reliability of the APECS application.

Authors

Institutions

Publication Details

Journal
Journal of Back and Musculoskeletal Rehabilitation
Published
2026-09-30
DOI
https://doi.org/10.1177/10538127261492775
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Validity and reliability of the APECS mobile application for assessing knee joint position sense during functional squat tasks in healthy adults

Eda Akbaş, Emin Ulaş Erdem, Öznur Güney, İsmail ALAK et al.
Journal of Back and Musculoskeletal Rehabilitation
Knee injuries and reconstruction techniques
article

Validity and reliability of the APECS mobile application for assessing knee joint position sense during functional squat tasks in healthy adults

Eda Akbaş, Emin Ulaş Erdem, Öznur Güney, İsmail ALAK, İlknur Tuğba Cavdar
article en

Abstract

BackgroundKnee joint position sense (JPS) is a vital component of proprioception, significantly impacting functional performance and clinical outcomes.ObjectiveThis study aimed to investigate the concurrent validity and the intra- and inter-tester reliability of APECS-derived JPS error measures during three different squat ranges.MethodsSixty-two participants (mean age: 25.5 ± 3.9 years) were evaluated across three sessions. Knee JPS was measured at low (30-50°), moderate (50-70°), and deep (70-90°) squat ranges. Concurrent validity was evaluated by comparing APECS-derived JPS error measures with digital goniometer-derived measures. Intra-tester reliability was assessed by comparing Sessions 2 and 3 (T1), and inter-tester reliability by comparing T1 and T2 in Session 3. JPS error was quantified using absolute (AAE), relative (RAE), and variable (VAE) angular errors.ResultsCorrelations between APECS- and digital goniometer-derived JPS error measures were low and non-significant across all ranges (r = -0.22 to 0.08). Intra-tester reliability was good only for AAE (ICC = 0.85) and RAE (ICC = 0.79) in the deep squat range, with poor reliability elsewhere. Inter-tester reliability was predominantly poor, with moderate reliability only for VAE in the moderate range (ICC = 0.69).ConclusionUnder the present protocol, APECS-derived JPS error measures showed limited agreement with digital goniometer-derived measures and inconsistent reliability across squat ranges and error parameters. These findings are specific to the present APECS-based assessment protocol and reference method and should not be generalized to the overall validity or reliability of the APECS application.

Journal of Back and Musculoskeletal Rehabilitation
Zonguldak Bülent Ecevit University (TR)
No poverty
Openalex Percentile: Top 9%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.