Clinical Comparison of Articulating Paper, Intraoral Scanner, and Jaw-Tracking Device for Occlusal Analysis

Recent advances in digital dentistry have transformed occlusal analysis through the introduction of new digital workflows for recording static and dynamic occlusal contacts. This clinical study aimed to evaluate the reliability and concordance of two digital clinical workflows, the Medit i700 intraoral scanner and the Tizian JMA-Optic jaw-tracking system, using 100 μm articulating paper as the reference comparator for static and dynamic occlusal-contact recordings. Materials and Methods: Twenty-six participants aged 20 to 25 years were included in this study. For each participant, static and dynamic occlusal contacts were recorded in maximum intercuspation position (MIP), protrusive, and right and left laterotrusive movements, using 100 μm articulating paper, Medit i700, and Tizian JMA-Optic system. Intra-rater reliability was assessed using ICC(A,1) for the quantitative number of MIP contacts and Cohen’s kappa for dynamic occlusal-contact recordings. Sensitivity, specificity, positive predictive value, and negative predictive value of the digital systems were evaluated relative to the articulating-paper reference comparator. Agreement between articulating paper and the two digital workflows was assessed using the intraclass correlation coefficient for the quantitative variables. Results: Intra-rater reliability was generally high but varied according to the recording method and occlusal-contact category. Overall, the Medit i700 showed numerically higher sensitivity and positive predictive value point estimates in several dynamic occlusal-contact categories than Tizian JMA-Optic, while specificity and negative predictive values were generally high for both systems. Both digital workflows showed good overall agreement with articulating paper in recording the number of occlusal contacts in MIP. Agreement was good at arch level, poor in the anterior regions, and moderate in the posterior regions. Conclusions: Both digital workflows showed generally high intra-rater reliability for dynamic occlusal recordings, with reliability varying according to the occlusal-contact category. Both systems demonstrated good agreement with the articulating-paper reference comparator for quantifying occlusal contacts in MIP, although substantial differences in measured contact area were observed. The numerical differences between Medit i700 and Tizian JMA-Optic should be interpreted descriptively rather than as evidence of superiority of either workflow. Although the digital systems provide valuable quantitative information for occlusal analysis, articulating paper remains a widely used conventional method for clinical identification of occlusal contacts and served as the reference comparator in the present study.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-09-30
DOI
https://doi.org/10.3390/jcm15197587
Primary Topic
Temporomandibular Joint Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Clinical Comparison of Articulating Paper, Intraoral Scanner, and Jaw-Tracking Device for Occlusal Analysis

Maria Jarda, Manuela Tăut, Smaranda Dana Buduru, Ștefan Cristian Vesa et al.
Journal of Clinical Medicine
Temporomandibular Joint Disorders
article

Clinical Comparison of Articulating Paper, Intraoral Scanner, and Jaw-Tracking Device for Occlusal Analysis

Maria Jarda, Manuela Tăut, Smaranda Dana Buduru, Ștefan Cristian Vesa, Manuela Manziuc, Cosmin Ifrim, Mara Mihaela Savu, Flavia Groza, Ana Ispas, George Burian, Daniela Popa
article en

Abstract

Recent advances in digital dentistry have transformed occlusal analysis through the introduction of new digital workflows for recording static and dynamic occlusal contacts. This clinical study aimed to evaluate the reliability and concordance of two digital clinical workflows, the Medit i700 intraoral scanner and the Tizian JMA-Optic jaw-tracking system, using 100 μm articulating paper as the reference comparator for static and dynamic occlusal-contact recordings. Materials and Methods: Twenty-six participants aged 20 to 25 years were included in this study. For each participant, static and dynamic occlusal contacts were recorded in maximum intercuspation position (MIP), protrusive, and right and left laterotrusive movements, using 100 μm articulating paper, Medit i700, and Tizian JMA-Optic system. Intra-rater reliability was assessed using ICC(A,1) for the quantitative number of MIP contacts and Cohen’s kappa for dynamic occlusal-contact recordings. Sensitivity, specificity, positive predictive value, and negative predictive value of the digital systems were evaluated relative to the articulating-paper reference comparator. Agreement between articulating paper and the two digital workflows was assessed using the intraclass correlation coefficient for the quantitative variables. Results: Intra-rater reliability was generally high but varied according to the recording method and occlusal-contact category. Overall, the Medit i700 showed numerically higher sensitivity and positive predictive value point estimates in several dynamic occlusal-contact categories than Tizian JMA-Optic, while specificity and negative predictive values were generally high for both systems. Both digital workflows showed good overall agreement with articulating paper in recording the number of occlusal contacts in MIP. Agreement was good at arch level, poor in the anterior regions, and moderate in the posterior regions. Conclusions: Both digital workflows showed generally high intra-rater reliability for dynamic occlusal recordings, with reliability varying according to the occlusal-contact category. Both systems demonstrated good agreement with the articulating-paper reference comparator for quantifying occlusal contacts in MIP, although substantial differences in measured contact area were observed. The numerical differences between Medit i700 and Tizian JMA-Optic should be interpreted descriptively rather than as evidence of superiority of either workflow. Although the digital systems provide valuable quantitative information for occlusal analysis, articulating paper remains a widely used conventional method for clinical identification of occlusal contacts and served as the reference comparator in the present study.

Journal of Clinical MedicineVol. 15(19)
Iuliu Hațieganu University of Medicine and Pharmacy (RO)
No poverty
Openalex Percentile: Top 8%
Temporomandibular Joint Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.