Abstract Background Conventional volumetric modulated arc therapy (VMAT) optimization relies on gradient‐based methods in which analytical gradients must be explicitly derived for each objective function and machine constraint. This dedicated mathematical derivation imposes substantial barriers to extending the optimization framework with new clinical objectives or delivery constraints, and the resulting CPU‐based implementations do not natively exploit modern GPU hardware. Purpose To develop an end‐to‐end differentiable VMAT optimization framework using computation graphs that enable automatic differentiation–based gradient computation for both fluence map optimization (FMO) and direct aperture optimization (DAO), while incorporating VMAT machine delivery constraints within a unified, GPU‐accelerated pipeline. Methods A two‐stage pipeline—fluence map optimization (FMO) followed by DAO—was developed. FMO reformulates dose calculation as a differentiable computation graph, enabling gradient computation for arbitrary objective functions including non‐smooth Heaviside step terms. For DAO, a novel analytically derived computation graph maps MLC leaf positions to delivered fluence through closed‐form time‐averaged bixel exposure integration with finite‐width boundary corrections, ensuring exact differentiability. Machine delivery constraints—including leaf collision, speed limits, and dose rate bounds—are incorporated as differentiable penalty terms for joint end‐to‐end optimization. Twenty lung cancer cases from the GDP‐HMM AAPM Challenge dataset (60 Gy/30 fractions) were optimized using objectives derived from clinical Eclipse reference plans and compared against MatRad and Eclipse. Results The proposed method achieved PTV D98 of 58.88 ± 0.33 Gy, comparable to Eclipse (59.07 ± 0.55 Gy, p = 0.26) and significantly higher than MatRad (57.27 ± 0.48 Gy, p < 0.001). The Paddick conformity index was 0.81 ± 0.06, comparable to Eclipse (0.84 ± 0.22, p = 0.48) and superior to MatRad (0.64 ± 0.11, p < 0.001). OAR sparing closely matched Eclipse: heart mean dose 10.74 ± 4.89 Gy vs. 11.55 ± 4.76 Gy; lung mean dose 15.33 ± 3.50 Gy vs. 16.70 ± 3.29 Gy; LAD mean dose 9.55 ± 4.97 Gy vs. 9.05 ± 3.94 Gy ( p = 0.18). MatRad achieved lower heart doses at the cost of degraded PTV coverage and conformity. Optimization time was significantly shorter (59.28 ± 43.95 s vs. 390.30 ± 184.90 s, p < 0.001), while delivery times were equivalent ( p = 0.92). Conclusions The proposed differentiable VMAT framework demonstrated superior goal‐directed optimization fidelity compared with MatRad—more reliably translating objectives into intended dosimetric outcomes—achieving plan quality approaching clinical Eclipse plans with faster optimization.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-09-30
DOI
https://doi.org/10.1002/mp.70685
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

End‐to‐end differentiable volumetric modulated arc therapy optimization via computation graph–driven automatic differentiation

Hongkai Wang, Wenzheng Sun, Wenlong Xia, Bin Liang
Medical Physics
Advanced Radiotherapy Techniques
article

End‐to‐end differentiable volumetric modulated arc therapy optimization via computation graph–driven automatic differentiation

Hongkai Wang, Wenzheng Sun, Wenlong Xia, Bin Liang
article en

Abstract

Abstract Background Conventional volumetric modulated arc therapy (VMAT) optimization relies on gradient‐based methods in which analytical gradients must be explicitly derived for each objective function and machine constraint. This dedicated mathematical derivation imposes substantial barriers to extending the optimization framework with new clinical objectives or delivery constraints, and the resulting CPU‐based implementations do not natively exploit modern GPU hardware. Purpose To develop an end‐to‐end differentiable VMAT optimization framework using computation graphs that enable automatic differentiation–based gradient computation for both fluence map optimization (FMO) and direct aperture optimization (DAO), while incorporating VMAT machine delivery constraints within a unified, GPU‐accelerated pipeline. Methods A two‐stage pipeline—fluence map optimization (FMO) followed by DAO—was developed. FMO reformulates dose calculation as a differentiable computation graph, enabling gradient computation for arbitrary objective functions including non‐smooth Heaviside step terms. For DAO, a novel analytically derived computation graph maps MLC leaf positions to delivered fluence through closed‐form time‐averaged bixel exposure integration with finite‐width boundary corrections, ensuring exact differentiability. Machine delivery constraints—including leaf collision, speed limits, and dose rate bounds—are incorporated as differentiable penalty terms for joint end‐to‐end optimization. Twenty lung cancer cases from the GDP‐HMM AAPM Challenge dataset (60 Gy/30 fractions) were optimized using objectives derived from clinical Eclipse reference plans and compared against MatRad and Eclipse. Results The proposed method achieved PTV D98 of 58.88 ± 0.33 Gy, comparable to Eclipse (59.07 ± 0.55 Gy, p = 0.26) and significantly higher than MatRad (57.27 ± 0.48 Gy, p < 0.001). The Paddick conformity index was 0.81 ± 0.06, comparable to Eclipse (0.84 ± 0.22, p = 0.48) and superior to MatRad (0.64 ± 0.11, p < 0.001). OAR sparing closely matched Eclipse: heart mean dose 10.74 ± 4.89 Gy vs. 11.55 ± 4.76 Gy; lung mean dose 15.33 ± 3.50 Gy vs. 16.70 ± 3.29 Gy; LAD mean dose 9.55 ± 4.97 Gy vs. 9.05 ± 3.94 Gy ( p = 0.18). MatRad achieved lower heart doses at the cost of degraded PTV coverage and conformity. Optimization time was significantly shorter (59.28 ± 43.95 s vs. 390.30 ± 184.90 s, p < 0.001), while delivery times were equivalent ( p = 0.92). Conclusions The proposed differentiable VMAT framework demonstrated superior goal‐directed optimization fidelity compared with MatRad—more reliably translating objectives into intended dosimetric outcomes—achieving plan quality approaching clinical Eclipse plans with faster optimization.

Medical PhysicsVol. 53(10)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Cancer Hospital of Chinese Academy of Medical Sciences (CN), Second Affiliated Hospital of Zhejiang University (CN)
Decent work and economic growth
Openalex Percentile: Top 12%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.