Agreement Between Echocardiography and Ultrasonic Cardiac Output Monitoring (USCOM) for Hemodynamic Assessment in Pediatric Patients: A Bland–Altman Analysis

ABSTRACT Background Echocardiography is widely used for non‐invasive measurements of stroke volume and cardiac output, while Ultrasonic Cardiac Output Monitor (USCOM) offers an alternative Doppler‐based approach. Whether these two modalities can be used interchangeably in clinical practice remains unclear. This study aims to evaluate the correlation and agreement between echocardiography and USCOM for hemodynamic assessment. Methods A total of 44 pediatric patients underwent hemodynamic assessment using echocardiography and sequential USCOM measurement during the same evaluation. Spearman's rank correlation was used to assess the relationship between methods. Agreement was evaluated using Bland‐Altman analysis. Results Strong correlations were found for stroke volume (SV; r = 0.97), cardiac output (CO; r = 0.95), cardiac index (CI; r = 0.91), stroke volume index (SVI; r = 0.90), and aortic valve (AV) diameter ( r = 0.91; p < 0.001), with a moderate correlation for left ventricular outflow tract (LVOT) velocity ( r = 0.64, p < 0.001). Bland‐Altman analysis revealed echocardiography produced lower values of all parameters compared to USCOM. Significant proportional bias was identified for SV, SVI, CO, and CI (all p ≤ 0.006), indicating that two methods increased disagreement with higher measured values. AV diameter and LVOT velocity showed no significant proportional bias and narrower limits of agreement. Conclusions Although echocardiography and USCOM correlate strongly for hemodynamic parameters, clinically meaningful systematic bias and proportional error limit their interchangeability for volumetric flow measurements. These devices should not be used interchangeably for quantitative hemodynamic monitoring, particularly in high‐output states.

Authors

Institutions

Publication Details

Journal
Echocardiography
Published
2026-09-30
DOI
https://doi.org/10.1111/echo.70645
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Agreement Between Echocardiography and Ultrasonic Cardiac Output Monitoring (USCOM) for Hemodynamic Assessment in Pediatric Patients: A Bland–Altman Analysis

Saviga Sethasathien, Theerapon Jariyasakoolroj, Suchaya Silvilairat, Orana Arsasuwan
Echocardiography
Hemodynamic Monitoring and Therapy
article

Agreement Between Echocardiography and Ultrasonic Cardiac Output Monitoring (USCOM) for Hemodynamic Assessment in Pediatric Patients: A Bland–Altman Analysis

Saviga Sethasathien, Theerapon Jariyasakoolroj, Suchaya Silvilairat, Orana Arsasuwan
article en

Abstract

ABSTRACT Background Echocardiography is widely used for non‐invasive measurements of stroke volume and cardiac output, while Ultrasonic Cardiac Output Monitor (USCOM) offers an alternative Doppler‐based approach. Whether these two modalities can be used interchangeably in clinical practice remains unclear. This study aims to evaluate the correlation and agreement between echocardiography and USCOM for hemodynamic assessment. Methods A total of 44 pediatric patients underwent hemodynamic assessment using echocardiography and sequential USCOM measurement during the same evaluation. Spearman's rank correlation was used to assess the relationship between methods. Agreement was evaluated using Bland‐Altman analysis. Results Strong correlations were found for stroke volume (SV; r = 0.97), cardiac output (CO; r = 0.95), cardiac index (CI; r = 0.91), stroke volume index (SVI; r = 0.90), and aortic valve (AV) diameter ( r = 0.91; p < 0.001), with a moderate correlation for left ventricular outflow tract (LVOT) velocity ( r = 0.64, p < 0.001). Bland‐Altman analysis revealed echocardiography produced lower values of all parameters compared to USCOM. Significant proportional bias was identified for SV, SVI, CO, and CI (all p ≤ 0.006), indicating that two methods increased disagreement with higher measured values. AV diameter and LVOT velocity showed no significant proportional bias and narrower limits of agreement. Conclusions Although echocardiography and USCOM correlate strongly for hemodynamic parameters, clinically meaningful systematic bias and proportional error limit their interchangeability for volumetric flow measurements. These devices should not be used interchangeably for quantitative hemodynamic monitoring, particularly in high‐output states.

EchocardiographyVol. 43(10)
Chiang Mai University (TH)
Openalex Percentile: Top 9%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Agreement Between Echocardiography and Ultrasonic Cardiac Output Monitoring (USCOM) for Hemodynamic Assessment in Pediatric Patients: A Bland–Altman Analysis — Saviga Sethasathien, Theerapon Jariyasakoolroj, et al. · Echocardiography (2026) | TGRS Research Map | TGRS