Balloon‐Stopper Retrieval and Peripheral Parking After Inadvertent Ostial Right Coronary Stent Deployment

BACKGROUND: Percutaneous treatment of right coronary artery (RCA) ostial lesions is technically challenging due to cardiorespiratory motion. CASE SUMMARY: We describe a 70-year-old man undergoing PCI for an ostial RCA lesion where a forceful cough caused complete stent expansion within the aortic root. The stent remained mechanically engaged to the delivery shaft. A 4.0 × 15 mm balloon was inflated at the guiding catheter tip as a "balloon stopper," enabling controlled retrieval and "peripheral parking" (intentional implantation) in the right brachial artery. DISCUSSION: This case illustrates the technical feasibility of a bailout strategy for selected fully expanded extracoronary stents when guidewire access is maintained. The balloon-stopper technique provided mechanical control during retrieval, while peripheral implantation allowed relocation of the stent when further extraction was considered potentially hazardous.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-09-30
DOI
https://doi.org/10.1002/ccd.70932
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Balloon‐Stopper Retrieval and Peripheral Parking After Inadvertent Ostial Right Coronary Stent Deployment

Tomas Cieza, Fernando Manuel Quevedo Candela, Guy Proulx
Catheterization and Cardiovascular Interventions
Coronary Interventions and Diagnostics
article

Balloon‐Stopper Retrieval and Peripheral Parking After Inadvertent Ostial Right Coronary Stent Deployment

Tomas Cieza, Fernando Manuel Quevedo Candela, Guy Proulx
article en

Abstract

BACKGROUND: Percutaneous treatment of right coronary artery (RCA) ostial lesions is technically challenging due to cardiorespiratory motion. CASE SUMMARY: We describe a 70-year-old man undergoing PCI for an ostial RCA lesion where a forceful cough caused complete stent expansion within the aortic root. The stent remained mechanically engaged to the delivery shaft. A 4.0 × 15 mm balloon was inflated at the guiding catheter tip as a "balloon stopper," enabling controlled retrieval and "peripheral parking" (intentional implantation) in the right brachial artery. DISCUSSION: This case illustrates the technical feasibility of a bailout strategy for selected fully expanded extracoronary stents when guidewire access is maintained. The balloon-stopper technique provided mechanical control during retrieval, while peripheral implantation allowed relocation of the stent when further extraction was considered potentially hazardous.

Catheterization and Cardiovascular Interventions
Lung Institute (US)
Sustainable cities and communities
Openalex Percentile: Top 9%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Balloon‐Stopper Retrieval and Peripheral Parking After Inadvertent Ostial Right Coronary Stent Deployment — Tomas Cieza, Fernando Manuel Quevedo Candela, et al. · Catheterization and Cardiovascular Interventions (2026) | TGRS Research Map | TGRS