Same‐Day Discharge After Cardiac Device Generator Replacement: Safety and Patient Acceptability

ABSTRACT Background Same‐day discharge after cardiac implantable electronic device generator replacement may reduce hospital resource use, but evidence regarding its safety and patient acceptability remains limited. We evaluated the feasibility, safety, and patient‐reported acceptability of a day‐surgery pathway for isolated generator replacement. Methods We conducted a multicenter retrospective observational study of consecutive adults undergoing isolated cardiac implantable electronic device generator replacement between February 2017 and October 2024. Procedures requiring lead revision, upgrade, extraction, or repositioning were excluded. Patients were managed either through a day‐surgery pathway with same‐day discharge or through an ordinary‐setting pathway. The primary endpoint was device‐related infection within 365 days. Secondary outcomes included pocket hematoma, patient preference, and recalled preprocedural anxiety assessed using the Amsterdam Preoperative Anxiety and Information Scale (APAIS) and the Anaesthesia and Surgery‐dependent Preoperative Anxiety (ASPA) scale, administered during follow‐up after the procedure. A hypothetical projection of bed‐day cost savings was also performed. Results A total of 416 procedures were analyzed: 216 in the day‐surgery group and 200 in the ordinary‐setting group. Within 365 days, device‐related infection occurred in 4 patients in the day‐surgery group and 5 in the ordinary‐setting group (1.9% vs. 2.5%; p = 0.743). One pocket hematoma occurred in the day‐surgery group and was managed conservatively without subsequent infection. Preference for day surgery was reported by 93.8% of evaluable patients in the day‐surgery group and 76.0% in the ordinary‐setting group (p < 0.001). Recalled preprocedural APAIS and ASPA scores were significantly lower in the day‐surgery group. Using published Italian hospital micro‐costing data as an illustrative benchmark, the 216 day‐surgery procedures corresponded to a hypothetical reduction in hospital resource consumption of approximately €159,808. Conclusions Same‐day discharge after isolated generator replacement was feasible and well accepted and was not associated with a detectable increase in device‐related infection within 365 days. Recalled preprocedural anxiety scores were lower among patients managed through the day‐surgery pathway, although these assessments were obtained retrospectively during follow‐up. Same‐day discharge may represent a resource‐saving organizational pathway for selected patients, but its economic impact requires assessment in a formal health‐economic analysis.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-09-30
DOI
https://doi.org/10.1111/pace.70459
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Same‐Day Discharge After Cardiac Device Generator Replacement: Safety and Patient Acceptability

Raffaele Mauriello, Gianluigi Comparone, Stefano Nardi, Lucio Addeo et al.
Pacing and Clinical Electrophysiology
Cardiac pacing and defibrillation studies
article

Same‐Day Discharge After Cardiac Device Generator Replacement: Safety and Patient Acceptability

Raffaele Mauriello, Gianluigi Comparone, Stefano Nardi, Lucio Addeo, Luigi Argenziano, Procolo Marchese, Antonio Rapacciuolo, Luigi Cocchiara, Teresa Strisciuglio, Francesca Gennaro, Alfonso Varriale, Giovanni Esposito, Benedetta Brescia, Mario Vaccariello
article en

Abstract

ABSTRACT Background Same‐day discharge after cardiac implantable electronic device generator replacement may reduce hospital resource use, but evidence regarding its safety and patient acceptability remains limited. We evaluated the feasibility, safety, and patient‐reported acceptability of a day‐surgery pathway for isolated generator replacement. Methods We conducted a multicenter retrospective observational study of consecutive adults undergoing isolated cardiac implantable electronic device generator replacement between February 2017 and October 2024. Procedures requiring lead revision, upgrade, extraction, or repositioning were excluded. Patients were managed either through a day‐surgery pathway with same‐day discharge or through an ordinary‐setting pathway. The primary endpoint was device‐related infection within 365 days. Secondary outcomes included pocket hematoma, patient preference, and recalled preprocedural anxiety assessed using the Amsterdam Preoperative Anxiety and Information Scale (APAIS) and the Anaesthesia and Surgery‐dependent Preoperative Anxiety (ASPA) scale, administered during follow‐up after the procedure. A hypothetical projection of bed‐day cost savings was also performed. Results A total of 416 procedures were analyzed: 216 in the day‐surgery group and 200 in the ordinary‐setting group. Within 365 days, device‐related infection occurred in 4 patients in the day‐surgery group and 5 in the ordinary‐setting group (1.9% vs. 2.5%; p = 0.743). One pocket hematoma occurred in the day‐surgery group and was managed conservatively without subsequent infection. Preference for day surgery was reported by 93.8% of evaluable patients in the day‐surgery group and 76.0% in the ordinary‐setting group (p < 0.001). Recalled preprocedural APAIS and ASPA scores were significantly lower in the day‐surgery group. Using published Italian hospital micro‐costing data as an illustrative benchmark, the 216 day‐surgery procedures corresponded to a hypothetical reduction in hospital resource consumption of approximately €159,808. Conclusions Same‐day discharge after isolated generator replacement was feasible and well accepted and was not associated with a detectable increase in device‐related infection within 365 days. Recalled preprocedural anxiety scores were lower among patients managed through the day‐surgery pathway, although these assessments were obtained retrospectively during follow‐up. Same‐day discharge may represent a resource‐saving organizational pathway for selected patients, but its economic impact requires assessment in a formal health‐economic analysis.

Pacing and Clinical Electrophysiology
University of Salerno (IT), Azienda Sanitaria Locale di Asti (IT), Federico II University Hospital (IT), Villa Pineta Hospital (IT), Nini Hospital (LB), University of Naples Federico II (IT)
Decent work and economic growth
Openalex Percentile: Top 12%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.