Hydrodynamic Modeling of a Ring-Type Magnetic Mixing System for Non-Newtonian Swine Digesta in an In Vitro Bioreactor Using a Calibrated SPH Model

Accurate reproduction of hydrodynamic conditions in artificial gastrointestinal tract (GIT) bioreactors is a key factor governing the reliability of laboratory assessments of the nutritional value of swine feeds within the framework of alternative in vitro testing. The high viscosity and non-Newtonian shear-thinning behavior of swine digesta cause magnetic decoupling in conventional stirrers and the formation of stagnant zones, whereas mechanical agitators compromise anaerobic conditions within the vessel. This study presents a hydrodynamic rationale for the parameters of a ring-type bladed mixing device based on analytical modeling and three-dimensional mesh-free smoothed particle hydrodynamics (SPH). The simulations were conducted at the Don Engineering Center. The analytical model comprises a two-term equation for hydrodynamic resistance torque in a fluid obeying the Ostwald–de Waele power law and a quasi-two-dimensional calculation of the volumetric velocity coefficient of variation. The numerical flow model based on the implicit incompressible SPH (IISPH) algorithm was calibrated against rotational-viscometer torque by adjusting the effective viscosity of the SPH fluid. For an experimental torque of 8.56 μN·m and measured viscosity of 0.038 Pa·s, the mean simulated torque was 8.68 μN·m (a discrepancy of 1.4%) at a calibrated effective viscosity of 0.00991 Pa·s. Three representative geometric and operating configurations of the mixing device were investigated using the calibrated model. In laminar shear Regime A, the analytical resistance estimate differed from the numerical result by 15.7%, whereas in Regimes B and C, characterized by developed three-dimensional circulation, the analytical model substantially overestimated torque because bulk fluid entrainment into circumferential motion and three-dimensional flow redistribution were not accounted for. On transitioning from Regime A to Regime B, the coefficient of variation of velocity magnitudes decreased from 128.45% to 48.70%, reaching 47.83% in Regime C. The findings characterize changes in flow structure and the applicability of analytical relationships to the comparative hydrodynamic assessment of ring-type mixing devices.

Authors

Publication Details

Journal
Agriculture
Published
2026-11-16
DOI
https://doi.org/10.3390/agriculture16222522
Primary Topic
Fluid Dynamics and Mixing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Hydrodynamic Modeling of a Ring-Type Magnetic Mixing System for Non-Newtonian Swine Digesta in an In Vitro Bioreactor Using a Calibrated SPH Model

Maxim Khanukaev, Fedor Yu. Zhigailov, Elena A. Portnova, Sergei K. Shebeko et al.
1 links
Agriculture
Fluid Dynamics and Mixing
article

Hydrodynamic Modeling of a Ring-Type Magnetic Mixing System for Non-Newtonian Swine Digesta in an In Vitro Bioreactor Using a Calibrated SPH Model

Maxim Khanukaev, Fedor Yu. Zhigailov, Elena A. Portnova, Sergei K. Shebeko, Andrey V. Butovchenko
article en

Abstract

Accurate reproduction of hydrodynamic conditions in artificial gastrointestinal tract (GIT) bioreactors is a key factor governing the reliability of laboratory assessments of the nutritional value of swine feeds within the framework of alternative in vitro testing. The high viscosity and non-Newtonian shear-thinning behavior of swine digesta cause magnetic decoupling in conventional stirrers and the formation of stagnant zones, whereas mechanical agitators compromise anaerobic conditions within the vessel. This study presents a hydrodynamic rationale for the parameters of a ring-type bladed mixing device based on analytical modeling and three-dimensional mesh-free smoothed particle hydrodynamics (SPH). The simulations were conducted at the Don Engineering Center. The analytical model comprises a two-term equation for hydrodynamic resistance torque in a fluid obeying the Ostwald–de Waele power law and a quasi-two-dimensional calculation of the volumetric velocity coefficient of variation. The numerical flow model based on the implicit incompressible SPH (IISPH) algorithm was calibrated against rotational-viscometer torque by adjusting the effective viscosity of the SPH fluid. For an experimental torque of 8.56 μN·m and measured viscosity of 0.038 Pa·s, the mean simulated torque was 8.68 μN·m (a discrepancy of 1.4%) at a calibrated effective viscosity of 0.00991 Pa·s. Three representative geometric and operating configurations of the mixing device were investigated using the calibrated model. In laminar shear Regime A, the analytical resistance estimate differed from the numerical result by 15.7%, whereas in Regimes B and C, characterized by developed three-dimensional circulation, the analytical model substantially overestimated torque because bulk fluid entrainment into circumferential motion and three-dimensional flow redistribution were not accounted for. On transitioning from Regime A to Regime B, the coefficient of variation of velocity magnitudes decreased from 128.45% to 48.70%, reaching 47.83% in Regime C. The findings characterize changes in flow structure and the applicability of analytical relationships to the comparative hydrodynamic assessment of ring-type mixing devices.

AgricultureVol. 16(22)
Fluid Dynamics and Mixing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon