Influence of pressure sensor equipped handpiece and vitreous removal on posterior capsule movement during occlusion break in porcine eyes

Abstract Posterior capsule stability is a key determinant of safety in phacoemulsification; however, the influence of the vitreous on its dynamics remains unclear. This non-clinical study evaluated the stabilizing effect of the Active Sentry (AS) handpiece and the impact of vitreous absence using an ex vivo vitrectomized porcine eye model. Posterior capsule elevation following an occlusion break was quantified across four vitrectomized groups (AS or Ozil [OZ] handpieces), with or without eyelid speculum [ES] and compared with previously reported vitreous-intact data from the same series using an identical protocol. At 20 mmHg intraocular pressure, the posterior capsule elevation ratio was significantly lower with the AS than with the OZ handpiece, both without ES (3.8 ± 1.3% vs. 8.4 ± 3.9%) and with ES (10.1 ± 12.3% vs. 20.0 ± 14.4%) (both P = 0.0010). Vitrectomized eyes showed reduced elevation compared with vitreous-intact eyes in the ES model: 10.1 ± 12.3% vs. 18.0 ± 19.1% with the AS ( P = 0.0215) and 20.0 ± 14.4% vs. 46.2 ± 20.2% with the OZ ( P = 0.0031). In conclusion, the AS handpiece stabilized the posterior capsule independently of vitreous support. Vitrectomized eyes did not show increased posterior capsule instability, and exploratory, independently sampled comparisons suggested that vitreous absence may be associated with attenuated elevation during surge events; this observation should be interpreted as hypothesis-generating.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-09-29
DOI
https://doi.org/10.1038/s41598-026-73396-9
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Influence of pressure sensor equipped handpiece and vitreous removal on posterior capsule movement during occlusion break in porcine eyes

Hisaharu Suzuki
Scientific Reports
Intraocular Surgery and Lenses
article

Influence of pressure sensor equipped handpiece and vitreous removal on posterior capsule movement during occlusion break in porcine eyes

Hisaharu Suzuki
article en

Abstract

Abstract Posterior capsule stability is a key determinant of safety in phacoemulsification; however, the influence of the vitreous on its dynamics remains unclear. This non-clinical study evaluated the stabilizing effect of the Active Sentry (AS) handpiece and the impact of vitreous absence using an ex vivo vitrectomized porcine eye model. Posterior capsule elevation following an occlusion break was quantified across four vitrectomized groups (AS or Ozil [OZ] handpieces), with or without eyelid speculum [ES] and compared with previously reported vitreous-intact data from the same series using an identical protocol. At 20 mmHg intraocular pressure, the posterior capsule elevation ratio was significantly lower with the AS than with the OZ handpiece, both without ES (3.8 ± 1.3% vs. 8.4 ± 3.9%) and with ES (10.1 ± 12.3% vs. 20.0 ± 14.4%) (both P = 0.0010). Vitrectomized eyes showed reduced elevation compared with vitreous-intact eyes in the ES model: 10.1 ± 12.3% vs. 18.0 ± 19.1% with the AS ( P = 0.0215) and 20.0 ± 14.4% vs. 46.2 ± 20.2% with the OZ ( P = 0.0031). In conclusion, the AS handpiece stabilized the posterior capsule independently of vitreous support. Vitrectomized eyes did not show increased posterior capsule instability, and exploratory, independently sampled comparisons suggested that vitreous absence may be associated with attenuated elevation during surge events; this observation should be interpreted as hypothesis-generating.

Scientific Reports
Suzuki (Japan) (JP)
Sustainable cities and communities
Openalex Percentile: Top 9%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.