OBJECTIVES: The aim of this feasibility study was to determine whether standardised bitewing radiographs of simulated restorations in artificial teeth provide sufficient radiographic visibility for faculty observers to visualise selected restorative features. The study did not assess students, learning outcomes, diagnostic accuracy, restoration quality, faculty calibration, reliability, grading validity, cognitive load, or readiness for clinical practice. MATERIALS AND METHODS: A laboratory-based feasibility study with a repeated-measures faculty-observer component was conducted using 17 radiographic specimens: five restorations for each of three composite resins, one amalgam restoration as a positive radiopaque control and one unrestored preparation as a negative reference. Digital bitewing radiographs were acquired under standardised conditions with a 1- to 10-mm aluminium step wedge. Ten restorative dentistry instructors rated the perceived ease of visualising contour, homogeneity, marginal adaptation and proximal contact using a five-category Likert-type instrument (1 = very easy to 5 = not possible). Because the same instructors evaluated multiple images, evaluator-level median ratings were analysed using Friedman repeated-measures tests, with paired Wilcoxon signed-rank comparisons and Holm adjustment. Kendall's W was reported as the Friedman effect-size estimate. RESULTS: The restorative materials were clearly distinguishable from the artificial tooth substrate. Filtek Z350 XT and Filtek Bulk Fill Posterior showed mean radiopacity values of 7.40 and 8.64 mm Al, respectively. Enamel Plus HRI and amalgam exceeded the measured 10-mm Al calibration range; extrapolated estimates were 11.90 and 10.92 mm Al, respectively, and were treated as estimates rather than directly calibrated measurements. Across restored conditions, ratings were predominantly in the 'very easy' or 'easy' categories. Overall condition effects were significant for all four parameters (Friedman p < 0.001; Kendall's W = 0.562-0.804). No Holm-adjusted pairwise differences were detected among restored conditions, whereas each restored condition differed from the unrestored reference (adjusted p = 0.0195-0.0410). CONCLUSION AND CLINICAL RELEVANCE: Under the controlled conditions of this feasibility study, standardised bitewing radiographs of restored artificial teeth provided sufficient visibility for faculty observers to visualise the four prespecified restorative features. These findings establish preliminary technical feasibility only; they do not establish diagnostic accuracy, restoration quality, educational benefit, assessment reliability, or grading validity. Larger and balanced studies using student-performed restorations, clinically realistic comparators, prespecified defect categories and formal reliability and learning-outcome analyses are required.

Authors

Institutions

Publication Details

Journal
European Journal Of Dental Education
Published
2026-09-29
DOI
https://doi.org/10.1111/eje.70314
Primary Topic
Dental Research and COVID-19
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Standardised Radiographic Visualisation in Preclinical Restorative Dentistry: A Feasibility Study Using Artificial Teeth

Gilbert Jorquera, Juan Guillermo Estay, Cristian Bersezio, Eduardo Godoy et al.
European Journal Of Dental Education
Dental Research and COVID-19
article

Standardised Radiographic Visualisation in Preclinical Restorative Dentistry: A Feasibility Study Using Artificial Teeth

Gilbert Jorquera, Juan Guillermo Estay, Cristian Bersezio, Eduardo Godoy, Paulo Gallardo, Esteban Pérez, Roque Arias
article en

Abstract

OBJECTIVES: The aim of this feasibility study was to determine whether standardised bitewing radiographs of simulated restorations in artificial teeth provide sufficient radiographic visibility for faculty observers to visualise selected restorative features. The study did not assess students, learning outcomes, diagnostic accuracy, restoration quality, faculty calibration, reliability, grading validity, cognitive load, or readiness for clinical practice. MATERIALS AND METHODS: A laboratory-based feasibility study with a repeated-measures faculty-observer component was conducted using 17 radiographic specimens: five restorations for each of three composite resins, one amalgam restoration as a positive radiopaque control and one unrestored preparation as a negative reference. Digital bitewing radiographs were acquired under standardised conditions with a 1- to 10-mm aluminium step wedge. Ten restorative dentistry instructors rated the perceived ease of visualising contour, homogeneity, marginal adaptation and proximal contact using a five-category Likert-type instrument (1 = very easy to 5 = not possible). Because the same instructors evaluated multiple images, evaluator-level median ratings were analysed using Friedman repeated-measures tests, with paired Wilcoxon signed-rank comparisons and Holm adjustment. Kendall's W was reported as the Friedman effect-size estimate. RESULTS: The restorative materials were clearly distinguishable from the artificial tooth substrate. Filtek Z350 XT and Filtek Bulk Fill Posterior showed mean radiopacity values of 7.40 and 8.64 mm Al, respectively. Enamel Plus HRI and amalgam exceeded the measured 10-mm Al calibration range; extrapolated estimates were 11.90 and 10.92 mm Al, respectively, and were treated as estimates rather than directly calibrated measurements. Across restored conditions, ratings were predominantly in the 'very easy' or 'easy' categories. Overall condition effects were significant for all four parameters (Friedman p < 0.001; Kendall's W = 0.562-0.804). No Holm-adjusted pairwise differences were detected among restored conditions, whereas each restored condition differed from the unrestored reference (adjusted p = 0.0195-0.0410). CONCLUSION AND CLINICAL RELEVANCE: Under the controlled conditions of this feasibility study, standardised bitewing radiographs of restored artificial teeth provided sufficient visibility for faculty observers to visualise the four prespecified restorative features. These findings establish preliminary technical feasibility only; they do not establish diagnostic accuracy, restoration quality, educational benefit, assessment reliability, or grading validity. Larger and balanced studies using student-performed restorations, clinically realistic comparators, prespecified defect categories and formal reliability and learning-outcome analyses are required.

European Journal Of Dental Education
Universidad de Los Andes, Chile (CL), Universidad Autónoma de Chile (CL), University of Chile (CL)
Openalex Percentile: Top 7%
Dental Research and COVID-19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.