Single- Versus Multi-Site Quadriceps Ultrasound Measurements and Their Associations With Physical Performance

Introduction: Skeletal muscle ultrasound of the quadriceps is often performed at the mid-thigh rather than other muscle regions. Moreover, most studies have examined associations between ultrasound-derived measures and a single functional outcome. The first aim was to determine whether averaging ultrasound measurements across the quadriceps femoris provides estimates of muscle size and quality (echo intensity (EI)) comparable with a mid-thigh measurement. The second aim was to evaluate associations of muscle size and EI (multiple vs single site) with different physical performance tests. Methods: In this cross-sectional study, 30 adults (50% women; 24.9 ± 7.9 yr old) underwent ultrasound imaging for analysis of muscle size and EI of the vastus lateralis, rectus femoris, and vastus intermedius at 30%, 50%, and 70% of the femur length. Physical performance was assessed by isometric knee extension torque (laboratory test), stair climb (clinical test), and vertical jump (athletic test). Results: Muscle size averaged across the length of the muscle was smaller compared with single-site measures ( P = 0.03) but showed excellent agreement (intraclass correlation coefficient = 0.985). Muscle EI was similar between multiple versus single-site measurements ( P = 0.17). Multi-site size correlated more strongly with isometric knee extension torque ( r = 0.706, P < 0.001), whereas single-site measures correlated more with stair climb (r = 0.741, P < 0.001). Jump time showed comparable associations for multiple- and single-site measures of quadriceps muscle size ( r = 0.710–0.772) and EI ( r = −0.748 to −0.762; all P < 0.001). Conclusion: Single-site measurements tended to overestimate muscle size/quality relative to multi-site assessments. Muscle size from multiple sites was more strongly associated with isometric knee extension torque, whereas single-site measures better predicted stair-climb performance; jump time was equally associated with both. The imaging approach should be selected according to the functional outcome, as predictive value varies across tests.

Authors

Institutions

Publication Details

Journal
Translational Journal of the American College of Sports Medicine
Published
2026-09-29
DOI
https://doi.org/10.1249/tjx.0000000000000401
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Single- Versus Multi-Site Quadriceps Ultrasound Measurements and Their Associations With Physical Performance

Davi A. G. Mázala, Líbyna Thaynara Calandrelli Martins, Andrea T. Barton, Marcel Bahia Lanza et al.
Translational Journal of the American College of Sports Medicine
Lower Extremity Biomechanics and Pathologies
article

Single- Versus Multi-Site Quadriceps Ultrasound Measurements and Their Associations With Physical Performance

Davi A. G. Mázala, Líbyna Thaynara Calandrelli Martins, Andrea T. Barton, Marcel Bahia Lanza, Daniel F. McLaughlin, Evan R. Bota
article en

Abstract

Introduction: Skeletal muscle ultrasound of the quadriceps is often performed at the mid-thigh rather than other muscle regions. Moreover, most studies have examined associations between ultrasound-derived measures and a single functional outcome. The first aim was to determine whether averaging ultrasound measurements across the quadriceps femoris provides estimates of muscle size and quality (echo intensity (EI)) comparable with a mid-thigh measurement. The second aim was to evaluate associations of muscle size and EI (multiple vs single site) with different physical performance tests. Methods: In this cross-sectional study, 30 adults (50% women; 24.9 ± 7.9 yr old) underwent ultrasound imaging for analysis of muscle size and EI of the vastus lateralis, rectus femoris, and vastus intermedius at 30%, 50%, and 70% of the femur length. Physical performance was assessed by isometric knee extension torque (laboratory test), stair climb (clinical test), and vertical jump (athletic test). Results: Muscle size averaged across the length of the muscle was smaller compared with single-site measures ( P = 0.03) but showed excellent agreement (intraclass correlation coefficient = 0.985). Muscle EI was similar between multiple versus single-site measurements ( P = 0.17). Multi-site size correlated more strongly with isometric knee extension torque ( r = 0.706, P < 0.001), whereas single-site measures correlated more with stair climb (r = 0.741, P < 0.001). Jump time showed comparable associations for multiple- and single-site measures of quadriceps muscle size ( r = 0.710–0.772) and EI ( r = −0.748 to −0.762; all P < 0.001). Conclusion: Single-site measurements tended to overestimate muscle size/quality relative to multi-site assessments. Muscle size from multiple sites was more strongly associated with isometric knee extension torque, whereas single-site measures better predicted stair-climb performance; jump time was equally associated with both. The imaging approach should be selected according to the functional outcome, as predictive value varies across tests.

Translational Journal of the American College of Sports MedicineVol. 11(4)
University of Maryland, Baltimore (US), Universidade Estadual de Campinas (UNICAMP) (BR), Hospital de Clínicas da Unicamp (BR), Towson University (US)
Good health and well-being
Openalex Percentile: Top 22%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.