Evaluation of an ABO antibody immunoadsorption column for reduction of anti‐A and anti‐B isoagglutinin titers in group O platelet units

BACKGROUND: Clinical guidelines recommend transfusing ABO-identical platelets where possible. However, the short shelf life of platelets (5-7 days) and stock availability mean ABO-nonidentical platelet transfusions are sometimes unavoidable. Minor ABO-incompatible platelet transfusions carry a risk of hemolysis due to donor anti-A/B antibodies, and high-titer (HT)-negative units are preferred to mitigate this risk. To further mitigate this risk, we investigated whether an ABO antibody immunoadsorption column could reduce anti-A/B titers in group O platelet units while preserving platelet quality. STUDY DESIGN AND METHODS: Six group O double dose apheresis platelet units were pooled with HT-positive group O plasma and split into three arms: untreated control, single-pass filtration (Glycosorb ABO A/B-column), and double-pass using the same column. Anti A and anti B IgM and IgG titers were measured pre- and post-filtration using a gel card method. Platelet count, platelet volume, coagulation factors, and markers of platelet quality and activation were assessed after filtration and during storage. RESULTS: Anti-A and anti-B titers were decreased from titers of 128 to ≤4 (IgM) and from 512 to ≤8 (IgG) following a single pass through the immunoadsorption column. Reduced efficacy was observed following a second pass through the same column (≤32 (IgM) and ≤128 (IgG)). Filtration was not associated with substantial platelet loss, although changes in some metabolic and activation markers were observed during storage. DISCUSSION: The ABO antibody immunoadsorption column effectively reduced anti-A/B titers in group O platelet units and may offer a strategy to increase the availability of low-titer platelets for transfusion.

Authors

Institutions

Publication Details

Journal
Transfusion
Published
2026-09-29
DOI
https://doi.org/10.1111/trf.70410
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Evaluation of an ABO antibody immunoadsorption column for reduction of anti‐A and anti‐B isoagglutinin titers in group O platelet units

Gillian Eastwood, Melanie J. Robbins, Sian Huish, Rebecca A. Cardigan et al.
Transfusion
Blood transfusion and management
article

Evaluation of an ABO antibody immunoadsorption column for reduction of anti‐A and anti‐B isoagglutinin titers in group O platelet units

Gillian Eastwood, Melanie J. Robbins, Sian Huish, Rebecca A. Cardigan, KURT G. I. NILSSON, Susan Proffitt
article en

Abstract

BACKGROUND: Clinical guidelines recommend transfusing ABO-identical platelets where possible. However, the short shelf life of platelets (5-7 days) and stock availability mean ABO-nonidentical platelet transfusions are sometimes unavoidable. Minor ABO-incompatible platelet transfusions carry a risk of hemolysis due to donor anti-A/B antibodies, and high-titer (HT)-negative units are preferred to mitigate this risk. To further mitigate this risk, we investigated whether an ABO antibody immunoadsorption column could reduce anti-A/B titers in group O platelet units while preserving platelet quality. STUDY DESIGN AND METHODS: Six group O double dose apheresis platelet units were pooled with HT-positive group O plasma and split into three arms: untreated control, single-pass filtration (Glycosorb ABO A/B-column), and double-pass using the same column. Anti A and anti B IgM and IgG titers were measured pre- and post-filtration using a gel card method. Platelet count, platelet volume, coagulation factors, and markers of platelet quality and activation were assessed after filtration and during storage. RESULTS: Anti-A and anti-B titers were decreased from titers of 128 to ≤4 (IgM) and from 512 to ≤8 (IgG) following a single pass through the immunoadsorption column. Reduced efficacy was observed following a second pass through the same column (≤32 (IgM) and ≤128 (IgG)). Filtration was not associated with substantial platelet loss, although changes in some metabolic and activation markers were observed during storage. DISCUSSION: The ABO antibody immunoadsorption column effectively reduced anti-A/B titers in group O platelet units and may offer a strategy to increase the availability of low-titer platelets for transfusion.

Transfusion
NHS Blood and Transplant (GB), University of Cambridge (GB)
Openalex Percentile: Top 15%
Blood transfusion and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.