Effect of Temperature and Age on the Bond and Mechanical Properties of Polymer Concrete with Fiber Reinforcement
Polymer concretes with fiber reinforcement have many desirable properties when compared to cementitious concretes, including rapid development of mechanical properties, excellent bond to concrete and other substrates, high tensile strength, and resistance to abrasion and aggressive chemical environments. However, their use as a structural material has been limited, in part, by temperature-dependent mechanical properties, affecting bond and development of steel reinforcement, deformation of structural elements, and section capacity of structural members. This research investigated the development of mechanical properties for a commercially available polymer concrete with fiber reinforcement to determine the effects of temperature on compressive strength, elastic modulus, modulus of rupture, and pull-out bond strength. The compressive, flexural, and bond strengths of the tested polymer concrete with fiber reinforcement were over 70% of their 7 d values within 4 h after mixing when cured at laboratory temperature, demonstrating the rapid development of mechanical properties that is possible with polymer binders. The average 7 d compressive strength across the experimental program was 62.2 MPa at 25 °C, with the measured elastic modulus and modulus of rupture roughly half and three times that of estimated values using established code relationships and the measured compressive strength, respectively. The pull-out bond strength at 25 °C was found to be similar to non-proprietary ultra-high performance and polymethyl methacrylate concretes, and the variation in mechanical properties with temperature was roughly linear and independent of the mechanical property tested when normalized by the value at laboratory temperature. This limited test series supports the structural use of polymer concrete with fiber reinforcement, when in-service temperature is expressly considered in the design process, although further testing is needed to develop rational design procedures.
Authors
- Travis Thonstad (ORCID: https://orcid.org/0000-0002-1575-3617)
- Carolyn Donohoe (ORCID: https://orcid.org/0000-0002-2954-5384)
- Andrew Olstad (ORCID: https://orcid.org/0009-0005-0849-4273)
Institutions
- Oregon State University (US)
- University of Washington (US)
Publication Details
- Journal
- Fibers
- Published
- 2026-09-29
- DOI
- https://doi.org/10.3390/fib14100111
- Primary Topic
- Innovative concrete reinforcement materials
- Type
- article
- Field-Weighted Citation Impact
- 0.00