Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging

Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retrospectively evaluated 125 patients who underwent dual-source photon-counting CTA scans of thoracic arteries. We reconstructed standard CT images at 120 kV and VMI series at 15 keV intervals, ranging from 40 to 100 keV, and conducted quantitative and qualitative image analyses. For quantitative analysis, we assessed vascular CT numbers and contrast-to-noise ratio (CNR). For qualitative evaluation, three board-certified radiologists independently rated image quality, vascular contrast, and diagnostic assessability of the thoracic arteries using a five-point scale. Results: Quantitative image analysis revealed that 40 keV VMI reconstructions exhibited the highest mean CT value (HU: 1205 ± 286) and CNR (29.22 ± 9.13), followed by the 55 keV series (HU: 679 ± 161, CNR: 22.54 ± 7.36), significantly improved compared to higher keV levels and the standard 120 kV CT series (p < 0.001). Qualitative analysis showed the highest rating scores for 55 keV reconstructions, significantly higher than those of VMI series at higher energy levels and the standard 120 kV series (p < 0.001). Conclusions: VMI reconstructions at low energy levels (40–55 keV) significantly enhance vascular CTvalue and CNR, offering superior image quality and diagnostic assessability for thoracic arteries compared to standard CT series in photon-counting CTA.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-09-28
DOI
https://doi.org/10.3390/diagnostics16193145
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging

Christian Booz, Tommaso D’Angelo, Thomas Joseph Vogl, Leon David Gruenewald et al.
Diagnostics
Advanced X-ray and CT Imaging
article

Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging

Christian Booz, Tommaso D’Angelo, Thomas Joseph Vogl, Leon David Gruenewald, İbrahim Yel, Jennifer Gotta, Hanns Leonhard Kaatsch, Leona S. Alizadeh, Daniel Dillinger, Giuseppe Mauro Bucolo, Philipp Reschke, Daniel Overhoff, Andreea I. Nica, Vitali Koch, Stephan Waldeck, Katrin Eichler, Scherwin Mahmoudi
article en

Abstract

Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retrospectively evaluated 125 patients who underwent dual-source photon-counting CTA scans of thoracic arteries. We reconstructed standard CT images at 120 kV and VMI series at 15 keV intervals, ranging from 40 to 100 keV, and conducted quantitative and qualitative image analyses. For quantitative analysis, we assessed vascular CT numbers and contrast-to-noise ratio (CNR). For qualitative evaluation, three board-certified radiologists independently rated image quality, vascular contrast, and diagnostic assessability of the thoracic arteries using a five-point scale. Results: Quantitative image analysis revealed that 40 keV VMI reconstructions exhibited the highest mean CT value (HU: 1205 ± 286) and CNR (29.22 ± 9.13), followed by the 55 keV series (HU: 679 ± 161, CNR: 22.54 ± 7.36), significantly improved compared to higher keV levels and the standard 120 kV CT series (p < 0.001). Qualitative analysis showed the highest rating scores for 55 keV reconstructions, significantly higher than those of VMI series at higher energy levels and the standard 120 kV series (p < 0.001). Conclusions: VMI reconstructions at low energy levels (40–55 keV) significantly enhance vascular CTvalue and CNR, offering superior image quality and diagnostic assessability for thoracic arteries compared to standard CT series in photon-counting CTA.

DiagnosticsVol. 16(19)
Goethe University Frankfurt (DE), Heidelberg University (DE), University Medical Center of the Johannes Gutenberg University Mainz (DE), University Hospital Frankfurt (DE), Azienda Ospedaliera Universitaria Policlinico "G. Martino" (IT), University Medical Centre Mannheim (DE), Bundeswehrzentralkrankenhaus Koblenz (DE), Bundeswehr, Medizinische Fakultät Mannheim
Affordable and clean energy
Openalex Percentile: Top 22%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.